Things to check before calling the Technical Service

General requirements for operation
What to do if ...
... the appliance does not work ...
Check that it is plugged in properly.
Check that there is power in the mains
supply. Check that no fuses have been
tripped.
Set the thermostat to its minimum
temperature position.
... the appliance does not work and the
symbol indicating that the condensed
water tank is full is displayed on the
screen ...
Position the indoor unit on a flat surface. If
the symbol does not disappear, empty the
water tank. (See instructions in "Air
conditioning").
Check the condition of the flexible hose. It
should not be crushed or restricted.
The difference in height between the indoor
and outdoor units should be no greater than
1.5m.
... the appliance works for a period of time,
but then turns itself off before the room
reaches the set temperature ...
Make sure that the air intakes and outlets
are not obstructed.
Should the outdoor temperature rise above
43°C, the appliance may turn itself off for a
short period of time, after which it then turns
itself back on again. Should either the
indoor or the outdoor temperature fall below
20ºC, the appliance may turn itself off
temporarily in order to prevent frost or ice
from forming on the evaporator.
Make sure that the connection between the
outdoor and indoor units is properly fitted.
.. the appliance does not reduce room
temperature sufficiently ...
Make sure that windows or doors are
opened as little as possible (to minimise the
entry of outdoor air). This is particularly
important when a window or door must be
left ajar to accommodate the flexible hose.
Check the condition of the flexible hose. It
should not be crushed or restricted.
Lower blinds to reduce direct sunlight.
... the appliance is connected, but the
compressor does not work...
The temperature inside the room must be
higher than 18
air conditioning functions to work.
The room has reached the set temperature.
If you turn the appliance off after it has
been working for a period of time and then
try to turn it back on again immediately, it
takes a certain amount of time before the
compressor starts up again. This period of
time is required in order to ensure correct
appliance operation.
... water drips from the outdoor unit ...
Check that the outdoor unit is level.
Check that the outdoor unit is not lower
than the indoor unit.
Check that the plug is fitted correctly.
... there is water on the upper and side air
directors or in the basic filter housing ...
There is no cause for concern. This is
normal.
... the fault symbol is displayed on the
screen ...
Get in touch with an authorised dealer,
customer service or the manufacturer's
Technical Service Network.
Noise
... the appliance makes a lot of noise ...
Some noise is normal and other types of
noise can be solved easily. You need to be
able to distinguish between these types of
noise:
Perfectly normal noise
The sound of water flowing in cycles,
gurgling, is due to the pump, which
circulates the water to enhance the power
of the appliance.
46