If the accessories are too long, you can cut
one of them in order to adapt the assembly
to the thickness of the wall, Fig. 15.
This accessory can be fitted to the wall with
screws and wall plugs or silicon, plaster, etc.
Fig. 16
If do not wish or need to use the air-
conditioning, remove the hose from the hole
and close the covers on the accessory to
close the hole in the wall.
Separating the flexible hose from the
indoor unit
The hose must be dismantled from the indoor
unit in order to fit it through the wall (this is
only possible on models with disconnectable
hose). To do this, proceed as follows:
Disconnect the appliance from the mains
electricity supply.
Remove cover F, Fig. 1, from the indoor
unit. The flexible hose join is now visible,
Fig. 18.
Preparing the appliance before use
Fig. 15
Fig. 17
Fig. 18
To extract the electrical connection, remove
the screw , Fig. 19 A and the cover which
conceals it. Press the tabs on the side of
the connector carefully and remove it from
its housing, Fig. 19 B.
A
Dismantle the condensed water drainage
tube by turning it a 1/4 turn anti-clockwise
and remove it, Fig. 20. Be particularly
careful when removing this tube as some of
the water it contains may splash.
Keep tab A, which secures the position of
the lever, pressed in. Pull it upwards (be
careful with the spring of the lever), making
sure that it remains at its maximum height,
Fig. 21.