Locating The Connecting Box For The Connection Cable In The Sauna Room - Helo ROXX Manuel Produit

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 60
Installation and User Manual HELO ROXX
Power Heater connection
cable H07RN-F/
60245 IEC 66
kW
mm
400 - 415V 3N~
6,0
5 x 1,5
9,0
5 x 2,5
Table 2 Connection cable and fuses

3.9. Locating the connecting box for the connection cable in the sauna room

A
3.
2.
Image 4 Location for the connection box
A = Specified minimum safety clearance
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box must be clear of
obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and regulations of the local energy
supplier.
Fuse
Heater connection Fuse
cable H07RN-F/
60245 IEC 66
A
mm
2
230 V 3~
3 x 10
4 x 2,5
3 x 16
4 x 6
A
Sauna heater
3.
2.
Heater connection
cable H07RN-F/
60245 IEC 66
A
mm
2
230 - 240V 1N~ / 2~
3 x 16
3 x 6
3 x 25
-------
1
Fuse
A
2
35
------
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1118-60-04051118-90-0405

Table des Matières