Proximity Key Reader Configuration - Urmet 1784/45 Notice D'installation Et Utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26

5. PROXIMITY KEY READER CONFIGURATION

Proceed as follows to confi gure the device:
1) Power on the device and check that the following are displayed in sequence:
− the indication (display test);
− the caption (Initialization)
for a few seconds;
− the two-color led changes from red to green and back to red again in sequence;
− the fl ashing dot, which indicates that the device is operating correctly, (only if the display is enabled
by means of dip-switch 2).
2) Press the confi guration button (5) briefl y: the following will appear on the display in sequence:
− the SW version of the device (e.g.);
− the indication.
3) Press the confi guration button again briefl y to access the MASTER key storage procedure; the display
will show:
4) Complete the installation of the device: all subsequent operations can be performed by accessing the
front panel only.
5) From minimum 1 to maximum three MASTER keys can be defi ned. The MASTER keys will be used
subsequently to program the device, its parameters and user keys.
WARNING:
Once they have been numbered, the MASTER keys must be carefully preserved possibly by
the installation technician or administrator of the building: they can be used for subsequent
modifi cations (addition of new user keys, deletion of lost keys, etc.).
Present any key to be transformed into a MASTER key close to the front panel: one of the three bars
will move up to indicate that the key has been stored as MASTER and the buzzer will emit a continuous
beep.
To assure maximum reading effi ciency, the keys must be presented to the reader with the side with the
Urmet logo or the numeric code parallel to the front panel.
DS1784-005
19

Publicité

Table des Matières
loading

Table des Matières