WAHLBACH UTS10 Instructions De Montage Et D'utilisation page 19

Chauffe-eau sous évier 10 litres
Masquer les pouces Voir aussi pour UTS10:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical specifications
Description
Model
Mounting
Operating pressure
Temperature range
Distance between connections
Distance pipe to wall
Nominal voltage
Frequency
Nominal capacity
Nominal volume
Cable size
Maximum recommended water volume
Protection class
Type of Protection
Dimensions (HxWxD)
Water connection
Daily electricity
consumption (Qelec)
Load profile
Sound power level (LWA)
Energy efficiency (ηwh3)
3.
USER INSTRUCTIONS
The device must be filled with water before connection to
the electrical supply!
The device should always be connected to a safety unit!
DE GB NL FR
10L pressure boiler
Under-sink
vertical
0.8 MPa
7°C - 75°C
100mm
85mm
1/N/PE 230V
50Hz
2.0kW
10L
3x 1.0mm²
10,0L/min
I
IP24
457x310x280mm
G3/8"
1,172 kWh
XXS
15 dB
42.99%
19

Publicité

Table des Matières
loading

Table des Matières