External unit thermodynamic performances

Application 30/35
ARIANEXT
EXTERNALUNIT
04 kW
06 kW
08 kW
Application 40/45
ARIANEXT
EXTERNALUNIT
04 kW
06 kW
08 kW
External unit technical data
Refrigerant
Type
Charge (1) (kg)
Compressor
Type
Number
Tipo di avviamento
Condenser
Type
Number
Evaporator
Type
Weights
Expedition weight (kg)
Working range
T° heating water min/max °C
T° external air min/max
Hydraulics
Water volume (l)
Max water pressure ( kPa)
(1) (1)
Approximate values. Always refer to the specifi c value indicated on the data plate of the unit.
Working limits
70
65
60
55
50
45
B
40
35
30
25
20
15
10
-25
-20
-15
-10
-5
0
A - External air temperature (°C)
B - Flow water temperature (°C)
Temperature conditions °C
7/6_30/35°C
Rated power
Power
kW
consumption kW
4,08
0,99
5,76
1,34
7,16
1,80
Temperature conditions °C
7/6_30/35°C
Rated power
Power
kW
consumption kW
3,88
1,19
5,76
1,88
7,36
2,30
EXTERNALUNIT
R410A
1,195
1
Progressive
Plate heat exchanger
1
Finned tubes
60,6
20/60°C
-20/30°C
0,8
300
5
10
15
20
25
30
A
COP
Rated power
kW
4,12
2,78
4,30
3,46
3,98
4,16
COP
Rated power
kW
3,26
2,58
3,06
3,46
3,20
3,96
EXTERNALUNIT
04 kW
R410A
1,350
Rotary DC Inverter Technology
1
Progressive
Plate heat exchanger
1
Finned tubes
65,7
20/60°C
-20/30°C
0,8
300
Performances domestic hot water (DHW)
Tapping profi le following EN16147
DHW set point (°C)
Heat Pump function mode
Nominal stocking volume (liters)
DHW performance certifi ed with
or without electrical resistance
Heating up time (th)
Back-up power (Pes) (W)
Coeffi cient of performance (COPDHW)
35
Reference hot water temperature ('wh) (°C)
Maximum quantity of usable hot water (VMAX) (l)
Temperature conditions °C
-7/-8_ */35°C
Power
consumption kW
1,19
1,42
1,96
Temperature conditions °C
-7/-8_ */35°C
Power
consumption kW
1,28
1,62
2,31
EXTERNALUNIT
06 kW
R410A
1,810
1
Progressive
Plate heat exchanger
1
Finned tubes
71,4
20/60°C
-20/30°C
1,0
300
ARIANEXT EXTERNAL UNIT
04kW
06kW
XL
52
Alternate
180
without electrical resistance
2h13min
2h05min
45
2,50
53,0
240
COP
2,34
2,44
2,12
COP
2,02
2,14
1,71
08 kW
08kW
89
2h02min