Fisher & Paykel AeroCare Instructions D'installation Et Guide D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation instructions
CA
16
(EN)
Elevation adjustment
The input ratings of gas operated clothes dryers are based on their operation at sea level, and
need not be adjusted for operation at or below 2000 ft. (610 m) elevation. For operation at
elevations above 2000 feet (610 m), input ratings should be reduced at a rate of four percent per
1000 feet (305 m) elevation above sea level.
Installation must conform to all local codes and ordinances. In the absence of local codes and/or
ordinances, installation shall conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installation Code, CSA B149.1.
Gas supply connection
⁄ " NPT Male thread gas supply
1 ¾" (45 mm)
Note: add to vertical dimension the
distance between cabinet bottom to floor
Fig.6 Gas connection at rear of dryer

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Aerocare serie

Table des Matières