Option B, Install Access Panel - Metal Panel
Check that grounding clip is attached to the lower panel. Position
the lower panel behind the access panel. On some models there
is insulation on the access panel that must fall behind the
insulation on the lower panel.
Hold the 2 panels together and place them against dishwasher
leg. Using a Phillips or ¹⁄₄" screwdriver, reinstall the screws through
the holes in the access panel and the slots in the lower panel.
Check that the lower edge of the lower panel contacts the floor.
Adjust if necessary.
26
Tighten access panel screws.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Plug into a grounded 3 prong outlet. Check that power supply
cord does not touch dishwasher motor or lower part of
dishwasher tub.