VACUUM CHAMBER
PACKAGING MACHINES
CREATING VACUUM IN EXTERNAL CHANNELLED BAGS (See page 50)
1) Swicth the machine On and set the sealing value by selecting the SEAL function using
functions if present (it is advisable to program a special cycle).
2) Press the yellow button
3) When vacuum formation inside the bag is complete, i.e. the vacuum gauge indicates -1.0bar, press
Bag sealing follows and the cycle is completed with re-entry of air and opening of the lid.
WARNING!
THIS OPERATION IS ONLY POSSIBLE WITH CHANNELLED BAGS.
CHANNELLED
BAG
OIL CHANGE ALARM AND WORK CYCLES DISPLAY MODELS MULTIPLE 315-P4/P8 - VM12 - VM16
When the appliance has completed the maximum limit of 15,000 cycles, the display shows - immediately when the
machine is switched On and at the end of every work cycle - "AL oil", which indicates the need to change the pump
oil. Proceed with the operation as described in the "CHANGING PUMP OIL" paragraph.
The number of cycles performed can be displayed by pressing the
display shows "cic" and the number expressed in hundredths.
For example, "cic 048" indicates that 48×100 = 4800 work cycles have been reached
To reset the value, after pressing the four buttons mentioned above, immediately press
OPERATION AND PROGRAMMING MODELS VM18-VM18H-VM53-VM53H-VM19-VM1800-VM20-VM30
Attention: the appliance has two basic programs (models without gas option) or three basic programs (models with gas
option) that are factory-set. The user must proceed with programming the remaining programs according to his operating
requirements, depending on the type and quantity of product to be packed.
PROGRAMMING THE VAC, GAS, SEAL E SOFTAIR FUNCTIONS
MODELS VM18-VM18H-VM53-VM53H-VM19-VM1800-VM20-VM30
1) SWITCHING ON
Turn the ON/OFF main switch on the front of the machine to ON; the display shows the initials of the available options
for three seconds; then the program number is displayed by the first digit to the left.
2) SELECTING THE PROGRAM
Select the program (from 0 to 9) by means of arrows
GAS or SOFTAIR options are envisaged and set, the respective indicator LED lights up.
3) PROGRAMMING THE VAC FUNCTION (See page 50)
Enter the programming by pressing
Set the required value using arrows
required function.
REV. 00 - Cod.: 1500154
; position the bag at about 20 mm beyond the sealing bar (G), then start up the cycle by lowering lid (H).
G
: the program number starts flashing. Select the
and confirm by means of
at 2.7 - 3 seconds; deactivate the GAS and SOFTAIR
,
. Scroll through the programs; if the
: function; the VAC function LED starts flashing.
, or proceed with the programming by pressing the key for the
59
Operation and maintenance manual / Ed. 10 - 2005
USING THE APPLIANCE
.
H
and
keys simultaneously; the
.
GB
G B