4.3

Bushing Installation

METTLER TOLEDO bushings (locknuts supplied) are used for
installations in pipelines and tanks. Refer to Table 5 for bushing
specifications and to Figure 4 for a typical bushing installation.
Typical Bushing Installation
Bushing with locknut
Material
Part No
1.4435
52401947 G 1 1/2" NPT
with
52401943
Inspection
52401949
Certificate
3.1B
52401945
PVDF
52401948 G 1 1/2" NPT
52401944
52401950
52401946
Table 5: Hex-Head Bushing Specifications
4.4

Sanitary Installation

Part No
Description
52 401 952
Dairy adapter DN50
(DIN 11851)
52 401 953
Aseptic adapter DN50
(DIN 11864-1)
METTLER TOLEDO offers an adapter according to DIN 11851
(DN50) as well as an aseptic adapter DIN 11864-1 (DN50) for
the inductive sensors of the InPro 7200 series.
InPro 7200 Series
52 001 408
Figure 4: Bushing installation
Thread size
Rated pressure
MPa
1.75
R 1 1/2"
G 2" NPT
R 2"
1.0
R 1 1/2"
0.4
G 2" NPT
0.2
R 2"
Material
DIN 1.4435
DIN 1.4435
© 08/04 Mettler-Toledo GmbH, CH-8606 Greifensee
InPro 7200 Series
Max. temperature
at rated pressure
psi
°C
250
200
150
25
60
80
30
120
Certificate
3.1B Inspection Certificate
3.1B Inspection Certificate
Printed in Switzerland
°F
390
75
180
250

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Inpro 7200Inpro 7201Inpro 7202

Table des Matières