INSTALLATION PROCEDURE

Installation diagram of indoor unit
The auxiliary piping can be
connected to the left, rear left,
rear, right or bottom.
Right
Rear
Bottom
Rear left
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam
Mounting the installation plate
For installation of the indoor unit.
When the installation plate is directly mounted on the wall
1. Securely fix the installation plate to the wall by screwing it through the upper and lower fixing holes.
2. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in
the above figure.
3. Attach the installation plate horizontally to the wall.
When installing the installation plate with mounting screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in personal injury and property damage.
∅5 mm hole
Clip anchor
(local parts)
Left
Mounting screw
∅4 x 25 mm
Hook
Installation plate
Shield pipe
Mounting screw
Hook
1 7 0
1 2 0
10 0m m
Hook
Pipe hole
Thread
Indoor unit
CAUTION
4
For the rear left and left piping
Insert the cushion between the
indoor unit and wall, and tilt the
indoor unit for better operation.
Do not allow the drain hose to get
slack.
Make sure to run the drain hose
sloped downward.
55
18 0
80 10 0
0
10 0m m
Hook
Pipe hole
Weight
Mounting screw
Anchor bolt
Projection
15 mm or less
Wall
Cut the piping
hole sloped
slightly.
65
Installation
plate