Operating Data On The Rating Plate; Description Of The Dtrx3 Receiver; Features - Videotec DTRX3 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53

Operating data on the rating plate

The DTRX3 receiver is supplied with two rating plates in conformity with the EC standards.
The first plate contains:
• Model identification code (Extended 3/9 bar code)
• Power supply (Volt)
• Frequency (Hertz)
• Consumption (Watt)
The second plate indicates the serial number of the model (Extended 3/9 bar code).
During the installation phase, make sure that the power supply features of the receiver correspond to the
characteristics required. The use of unsuitable devices can lead to serious risks for the safety of the personnel and the
security of the plant.

Description of the DTRX3 receiver

The DTRX3 receiver is a microprocessor-based command receiver for the remote control of positioning
devices, motorised lenses, wiper, washer and auxiliary functions.

Features

• 17 functions: UP, DOWN, LEFT, RIGHT, AUTO, WASHER, WIPER, ZOOM TELE, ZOOM WIDE, FOCUS NEAR,
FOCUS FAR, IRIS OPEN, IRIS CLOSE, AUX1, AUX2, AUX3, AUX4
• Power supplied to the camera: 12 V
• 2 dry contacts 1 A 230 V~ or 1A 24 V~ (AUX3 and AUX4)
• 999 selectable addresses through dip switches or rotative switches
• Serial input selectable between RS-232 / Current Loop / RS485
• Selectable communication speed (38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 300 Baud)
• RS232, RS485 and Current Loop repeater for in-line configuration
• Possibility of using both polarity inversion lenses and common wire lenses
• Led indicating power supplied to the unit
• Led indicating active function
• EEPROM for the storage of active options
• 16 bit microcontroller with re-programmable Flash memory
• Trimmer for the adjustment of the lens voltage (from 3 V
• PRESET / SCAN / PATROL functions with an automatic recognition of the existing functions
• Possibility to memorise up to 14 PRESET functions (Pan &Tilt motor, lens) with standard Videotec protocol and 40
positions with MACRO protocol and Pelco D protocol (DCJ, DCT, DCIR keyboards)
• 4 alarm contacts set as N.O. or N.C.
=
max 350mA (AUX1) and 24 V~ max 180mA (AUX2)
up to 12 V
=
Pag. 4
=
)