BIP LD2-T017-04-BP _ _ / BP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.4
Identification parameters
Index
Parameters
Hex.
Dec.
0010
16
Vendor name
0011
17
Vendor text
0012
18
Product name
0013
19
Product ID
0014
20
Product text
0016
22
Hardware revision
0017
23
Firmware revision
0018
24
Application specific tag
Tab. 6-4:
IO-Link identification data
Access to subindex 0 addresses the entire
object of an index. Access of subindices >0
addresses the individual elements of an index.
Device Access Locks
With this standard parameter, it is possible to activate or
deactivate certain functions of the IO-Link device. With the
BIP, there is the option to lock the function of the
parameter manager. To do so, bit 1 of the 2-byte value
must be set to "1" (locked). In order to unlock the
parameter manager, bit 1 is set to "0".
Bit
Function
0
Lock parameter access
1
Lock parameter
management
2
Lock local
parameterization
3
Lock local user interface
4...15 Reserved
Tab. 6-5:
Lock parameter data
www.balluff.com
Data format (length)
StringT (7 bytes)
StringT (15 bytes)
StringT (21 bytes)
StringT (7 bytes)
StringT (28 bytes)
StringT (3 bytes)
StringT (8 bytes)
StringT (max. 32 bytes)
Lock
Supported
Not
supported
X
X
X
X
Access
Contents
Read only
"BALLUFF"
Read only
"www.balluff.com"
Read only
"BIP LD2-T017-04-BP_ _ "
Read only
"BIP_ _ _ _""
Read only
"Inductive Positioning System"
Read only
"v1.0"
Read only
"1.00.000"
Read/Write
***
Profile Characteristic
This parameter indicates which profile is supported by the
IO-Link device.
The inductive positioning system BIP support the Smart-
Sensor profile with a process data variable:
Subindex 1 ("Profile Identifier -> DeviceProfileID"):
0x0001 ("Smart Sensor Profile")
Subindex 2 ("Profile Identifier -> FunctionClassID"):
0x8000 ("Device Identification Objects")
Subindex 3 ("Profile Identifier -> FunctionClassID"):
0x8002 ("ProcessDataVariable")
PD Input Descriptor
This parameter describes the composition of the process
data variables used.
The process data variables are processed by the inductive
positioning system BIP (see Tab. 6-6 on page 12).
Application Specific Tag
The Application Specific Tag makes it possible to assign
the IO-Link device an arbitrary, 32-byte string. This can
only be used for application-specific identification and
applied in the parameter manager. The entire object is
accessed via subindex 0.
english