5.5
Installation on a wall
The console installed can be used to mount the oval gear meter on a suitable wall
(see Section
5.6
Installation of hose/pipe
The necessary hose-connecting elements are not supplied with the OGM version and must
be ordered separately (in accordance with type) from the range of accessories.
The necessary connecting elements must be used if installation in a rigid pipe is planned
(see Section 9, "Spare parts and accessories).
NOTE
5.6.1
Connection of hose/pipe
NOTE
Fig. 5.5
Hose connection
• Cut the hose (1) off at right angles
• Slip the union nut (2) and clamping
element (3) over the hose
• Slip the hose on to the cone (4) up to the
stop collar
• Position the O-ring seal (5) in the groove
provided on the connecting adapter (6)
• Connect hose with cone (4) and tighten
union nut (2)
417101446_Ovalradzaehler.doc
8.3.2
for installation dimensions).
The necessary hose-connecting elements are not supplied with the OGM version and must
be ordered separately (in accordance with type) from the range of accessories
(see Section 9, "Spare parts and accessories")
The necessary connecting elements must be ordered separately (both for the OGM and OGC
types) if installation in a rigid pipe is planned. (see Section 9, "Spare parts and accessories")
Adhere to information and instructions on the in-pack notes for the hose-connecting ele-
ments!
1
2
3
4
5
6
Fig. 5.6 Pipe connection
• Cut pipe (1a) off at right angles
• Slip union nut (2) over the pipe
• Weld/adhesively bond the insert (3a) to
the pipe
• Position the O-ring seal (5) in the groove
provided on the connecting adapter (6)
• Tighten the union nut (2)
- 26 -
1a
2
3a
5
6
Rev. 7-02.09