SPL2(TS) and SPL3(TS) user manual
not guarantee the audio quality of its output. If the threshold is crossed more than 14dB, the
OVERLOAD-LED starts blinking.
WARNING-indication. In music mode, the DETECT/REDUCTION/OVERLOAD-LED's are
active, while in live mode, the WARNING/SANCTION-LED's are active. When the measuring
microphone detects a sound pressure level higher than the allowed maximum, the WARNING-LED
will blink. If this situation persists, the blinking will become more intense (increasing duty-cycle). See
figure below. An external lamp can be connected with the same indication (via a solid-state-relay).
SANCTION-indication (live-mode). If the sound level remains exceeded, the blinking
WARNING-LED will light continuously. A few seconds after this, the SANCTION-LED will light, and
the current of the "Live mode OK"-pin will be switched off. This should be used to switch of the mains
from the live-bands amplifiers. After 30 seconds the limiter will reset, and power will be reapplied.
WARNING- and LIVE MODE OK- outputs
POWER ON-indication. This LED is on when the limiter is switched on.
POWER-switch. This is the mains switch of the limiter. When switched off, no audio will be fed
throuh the limiter, and all outputs will be shut off. When switched on, the limiter needs some