CONTROL UNIT
parameter FUNCTION .................................. DEFAULT
LO.
Logic ...........................................AUTOMATIC
PA.
Pause time.....................................
.
Cp
Weight class .............................
LAm.
Pre-fl ashing time ...............................
.
d1
Opening direction.................................
.
moD
Operator type ........................... with Z16 pinion
e1.
Wing power (FULL stroke) .................MAX
e2.
Wing power (SLOW stroke) ...............MAX
.
rp
Pre limit switch slowing ...................
.
ra
Post limit switch slowing ....................
.
rH
Final braking (hard) ........................ DISABLED
.
PSET
Restore factory settings (default)
.
man
Access MAINTENANCE menu
RadI
Access MEMORIES menu
Prof
Access ADVANCED programming
A3
Pedestrian opening ...............................30%
A7
Maximum torque time during startup ...
A8
Reverse time at end of motion ...........
LUM.
Display luminosity .............................. MEDIUM
Closing when photocell
Ad
uncovered .............................. reloads pause time
Ae
Auxiliary output ........................... WARNING LIGHT
AH.
Flashing light during pause ...................OFF
.
Ar
Aux. opening safety device .............PHOTOCELL
.
tf
Closing photocell test .....................DISABLED
.
An
Aux. opening safety device test ....DISABLED
Sensitivity to obstacle ...........
.
eC
.................................................
Ms.
Master/Slave function.....................DISABLED
.
rn
Deleting a remote control with address
.
r
tr
Deleting all remote controls
UPLd
Saving control unit data on Plug-in memory module
dnLd
Saving data from Plug-in memory module on control unit
ch1
Remote control Output channel
ch1
ch2
................................................. START
ch2
ch3
......................................PEDESTRIAN START
ch3;ch4
ch4
.........................................
AL.t
Movement Total counter - cannot be tampered
.
AL
P
Movement Partial counter for maintenance
.
AL
S
Sets maintenance cycle on
.
aL
r
Zero-sets the counter
IMPORTANT:
25
sec.
700
1000
÷
kg
3
sec.
0
200
mm.
0
sec.
0,5
sec.
0
sec.
0
(without encoder)
2
(with encoder)
DISABLED
AL.P
AL.P
BLUE
To select
- 24 -
SLIDE 230
SETTINGS
0 =
;
AUTOMATIC
1 =
;
FOUR STEPS
2 =
;
SUPER AUTOMATIC
3 =
SEMI AUTOMATIC WITH STOP
0 ÷ 60 (1
.
)
SEC
STEPS
0= 0÷100;
1= 100÷300;
4= 1000÷1300; 5= 1300÷1600; 6= 1600÷2000;
0 ÷ 9 (1
.
)
SEC
STEPS
0 ; 1
0=
Z16
; 1=
WITH
PINION
WITH
THRUST FORCE ELECTRONIC ADJUSTMENT
THRUST FORCE ELECTRONIC ADJUSTMENT
0 ÷ 8 (0 ÷ 800
- 100
MM
MM STEPS
0 ÷ 20 (0 ÷ 2
- 100
SEC
MSEC
0 ÷ 20 (0 ÷ 2
- 100
SEC
MSEC
def
(
RED TO CONFIRM
FLASHING
RED TO CONFIRM
RED TO CONFIRM
RED TO CONFIRM
1 ÷ 9 (10%
)
STEPS
1 ÷ 5 (0.5-
)
SECOND STEPS
0 ÷ 5 (
20
.)
A STEP DI
MSEC
0 ÷ 9
00=
; 01=
IMMEDIATELY
AT THE END OF PAUSE TIME
02=
10
. ; 03=
AFTER
SEC
AFTER A NEW COMPLETE PAUSE TIME
)
THE PAUSE TIME
0 =
; 1÷60 =
WARNING LIGHT
MINUTES COURTESY LIGHT
NOTE: only if not set on remote control
OR PEDESTRIAN START
0=
;
1=
(
OFF
ON
IN AUTOMATIC MODE
0=
;
1=
SAFETY EDGE
PHOTOCELL
0 =
; 1 =
DISABLED
STANDARD FOTOCELL TEST
0 =
; 1 =
DISABLED
STANDARD PHOTOCELL OR EDGE TEST
PHOTOCELL OR EDGE TEST
1 ÷ 9
-
DURING POWER ON
IF THE ENCODER IS PRESENT
(
) -
ITS DEFAULT
MODIFIABLE
WITHOUT THE ENCODER
(
DEFAULT IS ALLOWED
VALUE NOT MODIFIABLE
0=
;
1=
DISABLED
MASTER
0 ÷ 99 (
SEE PROGRAMMING REMOTE CONTROLS
RED TO CONFIRM
- (
RED TO CONFIRM
OPTIONAL PLUG
- (
RED TO CONFIRM
OPTIONAL PLUG
0 =
;
1 =
;
DISABLED
START
4 =
AUXILIARY OUTPUT USING EXTERNAL RELAIS
Ae
1÷60
1÷60
timer
if
=
sec.)
0000 ÷ 9999 (
1
INCREASES BY
0000 ÷ 9999 (1 = 10
MOVEMENTS
0000 ÷ 9999 (1 = 10
MOVEMENTS
-
-
EACH SETTING ZERO
SETS THE COUNTER
RED TO CONFIRM
RED
To confi rm
4 =
-
-
;
STEP
BY
STEP
5 =
;
MANNED
6 =
(
)
TIMER
START INPUT
;
7 =
PARK
8 =
PARK SPECIAL
2= 300÷700;
3=700÷1000;
Z20
PINION
: 0 (
) ÷ 99 (
MINIMUM
: 0 (
) ÷ 50 (
MINIMUM
)
.
)
STEPS
.
)
STEPS
L0
. =
)
CONCLUDED
(
COUNTING CONTINUES
ON
AFTER START
)
; 2 =
REFLEX FOTOCELL TEST
; 2=
,
THE PARAMETER TAKES
,
ONLY THE RELEVANT
!)
par. 4.3
SEE
;
2=
;
SLAVE
)
-
)
IN MEMORY MODULE
-
)
IN MEMORY MODULE
2 =
; 3 =
PEDESTRIAN START
(2 sec. pulse if
100
)
FOR EVERY
MOVEMENTS
AL.S
AL.r
) (
RESET USING
OR
)
100
WITH MINIMUM STEP
MOVEMENTS
AL.P
YELLOW
To exit
)
MAX
)
MAX
) ;
(
RELOADS
REFLEX
;
STOP
Ae
0
=
;
)

Publicité

Table des Matières
loading