Electric System Set-Up; Electrical Connections - Aprimatic Slide 230 Instructions D'installation, D'utilisation Et D'entretien

Platine de commande pour l'automatisation de portails coulissants 230 v
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.1.1
Using the Plug-in memory module (optional)
The Module saves the system functioning parameters
and the remote controls. When the module is permanently
installed on the control unit, the system uses the Module
memories. For the memory transfers it is necessary to carry
out the Upload or Download procedure.
Permanent installation
NOT powered Control Unit
insert the plug-in Memory Module
power up
if the functioning
parameters are
if the functio-
missing on the
ning para-
module
meters have
Init
is shown
been saved
on the display
in the module
press the YELLOW
memory
a n d BLUE f o r
system
approx. 3 sec
START-UP
L r n
; carry out
the self-teaching
when the displays switch off the system is ready to work
2.2

Electric system set-up

Before you install components you should prepare the
electrical connections of the control and safety devices in
the system, following the instructions given on the "Electrical
equipment setup diagram" in the instruction manual supplied
with the operator. Follow the instructions given in this manual
and the instructions given for each system component.
!
Warning
The system must only be installed by skilled personnel
qualifi ed in compliance with the regulations of the country
of installation (CEI 64 - 8 / EN 60335-1 standards).
2.3

Electrical connections

Check that all the connections are as specifi ed in the Layout dia-
gram below. Check that the cables are connected to the correct
inputs. Check that the minimum cable section is as specifi ed.
!
Warning
Switch OFF the mains power supply before you start
connecting up.
Before you connect up the product and accessories, check
them for damage.
IMPORTANT! Read and follow the instructions for all the
components installed.
Faulty connections can cause equipment operating faults
and may seriously damage the equipment. Failure to
connect up the equipment correctly will void your guarantee.
Do NOT use intercom or telephone cable.
IMPORTANT: Complete all connections and checks before
you connect up to the 230 V AC mains power supply.
!
The equipment must be earthed. Connect the earth to the earth terminals. Carry out the correct earth between the control
unit and the operator.
CONNECTING UP TO THE MAINS POWER SUPPLY
POWER SUPPLY - 230 V AC monophase 50 Hz.
Use a power supply cable with 3 wires and a minimum section of 1.5 mm
regulations. Choose the section of the cable to match the length of the line.
IMPORTANT ! Always install, upstream of the line, a mains switch which guarantees a multipole cut-off with minimum
contact opening of 3 mm (connect it to a 6 A differential overload switch with sensitivity of 30 mA).
SLIDE 230
Download/Upload
Powered Control Unit
carry out
Download or Upload
(see the par. Programming)
at the end
done
is shown on
the display
disconnect power,
t h e n p o w e r u p
again
CN1 10-pin connector for RPL-ECO receiver (alternative
CN2 3-pin Aprimatic connector for accessories; connection
CN3 Terminal board for built-in receiver antenna
- 17 -
J1 RS232 / Urmet interface serial connector
or DOUBLE (master-slave) OPTIONAL card connector
or remote programming keyboard OPTIONAL card con-
nector
J4 11-pin plug-in terminal board - connections for control
and accessory inputs
1-2 Flashing LED, 24 V DC - two-wire cable with min.
section 1 mm
2
. DO NOT use other types of fl ashing light!
3-2 Warning light/AUX output - 24 V DC output with
maximum load of 3 W.
4-8 Pedestrian opening start (N/O).
5 - 24 V power supply for ACCESSORIES.
6-8 Auxiliary safety devices (photocell, safety edge)
(N.C. safety contact).
7-8 Closing photocell input (N.C. safety contact)
9-10 STOP (N.C. safety contact) to stop the movement.
11-10 START (N.O.) to start the opening or closing.
J9 Plug-in terminal board - for limit switch/encoder con-
nections
J12 Plug-in memory module connector (OPTIONAL)
J13 Motor capacitor connection terminal board
J15 Removable terminal board - power for 230 V AC motor
output - 3-wire cables with minimum section of 1.5
mm
2
J16 Removable terminal board - safety edge and photocell
test input
M1 Removable terminal board - 230 V AC phase-neutral-
earth connection
JRX Connector for built-in receiver (CAUTION This connec-
tor can only be plugged in one way. Ensure that the
plug-in direction is correct. Do not force).
to built-in receiver)
for radio card compatible with UNICO receiver (alterna-
tive to built-in receiver) - Access control decoder
F1 Mains power supply and 230 V motor power supply
fuse
F3 External accessories protection fuse (24 V DC)
DL1 Power supply ON and FIRMWARE LED
LED display - to show the parameters and their
DS1
values
DS2
DS3
DS4
2
; the cable must comply with current electrical
CONTROL UNIT
tab. 3 -
Unit components

Publicité

Table des Matières
loading

Table des Matières