Instructions and user manual Device pH
Warning :
Under no circumstances the device will be connected in parallel on the power supply terminals of
the filtration pump "L" into the electrical case "M"
It is important to keep a minimum distance of 20cm between the probe "C" and the injection point
"H".
The injection point "H" must be placed the last on the hydraulic installation (see fig. 3)
In the case of an installation with redox and pH regulation, it is advised to put the two sensors side
by side and the pH injection before chlorine injection to minimize the risk of scale deposition on the
chlorine injection.
For optimal service life of your peristaltic tube, it is advised not to exceed a pressure of 1 bar and in
no case exceed a pressure of 1.5 bar (150 000 Pa).
The pH probe must be settled before the chlorine injection point, the salt chlorinator cell and the
heater.

3.3 Accessories mounting

3.3.1

Dimensions

3.3.2 Bracket
143 mm
6
102 mm
NOT065ENV02
Fig.4