3.0 INSTALLATION AND RECOMMENDATION

3.1 Recommendations

Install the pump in a dry place and well away from sources of heat, and in any case, at
environmental temperature not exceeding 40°C. The operating minimum temperature depends of
the liquid to be pumped, bearing in mind that it must always remain in a liquid state.
The pump is to be located where flooding cannot occur.
Carefully observe the national wiring rules in force in the various countries as regards of electrical
installations. For Australia and New Zeland, the rules references are in accordance with AS/NZS
3000.
A mean for disconnection from the supply mains must be present and must have a contact
separation in all poles that provide full disconnection under overvoltage category III.

3.2 Hydraulic and electric installations

L: Filtration pump already presents on your installation and intended to circulate the water sucked into the
pool to the filtration.
M:Electrical case already present on your installation that is intended to control your entire filtration.
N:Cable without plug for connection to the electrical case of the pool « M » either on
The terminals of auxiliary contact relay to the filtration pump "L"
The terminals in parallel with the coil A1and A2 of the relay filtration pump "L"
The voltage to be applied to this cable is 230V 240V. Thus the device will be powered only when the
filtration pump is on.
Power supply : 230V - 240 V
Max flow rate : 1,5 l/h
N
Fig. 3
Power : 10W
Max pressure : 1,5 bars (150 000 Pa)
5
NOT065ENV02
Coil A1
Coil A2
M : Inside Electrical case
of the swimming pool