Instructions and user manual Device pH
NOT065ENV02

7.1 Replacement of the peristaltic tube

Fig. 13
Ensure that the tube is properly lubricated with silicone grease.

7.2 Maintenance of the electrode

Over time, in addition to the normal wear of the electrode, according to the use and water quality which is
more or less calcareous, measurement will deteriorate. A thin layer of limestone with other elements
present in the pool water will deposit on the sensing element of the probe. To overcome this problem, it is
advisable to use the cleaning solution for electrode pH and redox AYACSOLNET02and follow the procedure
on the bottle.
We recommend you to change the electrode, if the measures do not give good results any more or than
the quality shown after the calibration is lower than 50, and to change the buffer solution if you have a
doubt on its quality after several usesor after the best before date.

7.3 DEVICE PH wintering

During the wintering, you must protect the peristaltic tube. It is advised to pump clean water to rinse the
peristaltic tube.It is then recommended to pump clean water to rinse the peristaltic tube, as described in
the section 4.2, set the pump rollers in the « 12:30 » position (see cons) to extend the life of the peristaltic
tube.