Auto Null; Operation In Snow And Water; Maintenance; Cleaning - RIDGID MR-10 Mode D'emploi

Masquer les pouces Voir aussi pour MR-10:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
MR-10 Magnetic Locator
Polarity can often aid the user when identify-
ing a target from non-targets as the polarity
may flip from positive to negative

AUTO NULL

In environments with a persistent magnetic
signal, such as along a chain link fence or a
metal building wall, the Auto Null feature allows
the locator be re-zeroed to eliminate the read-
ings from that persistent magnetic signal.
While in the persistent magnetic field (but a -
way from the objects that you are trying to lo-
cate), press the AUTO NULL button. The
Absolute signal strength should reset to zero
(Figure 10). Continue locate as before.
To turn off Auto Null and reset the unit to nor-
mal settings and sensitivity, cycle the power
OFF, then ON.
Before
AUTO NULL
After
AUTO NULL
Figure 10 – AUTO NULL Feature
8

Operation in Snow and Water

The lower 24" (610 mm) of the locator, below
the display, can be submerged into water or
buried in snow.
Do not submerge the display unit
NOTI E
in water. The MR-10 Magnetic Locator is wa-
terproof up to display only. The display/control
panel is not waterproof, and excessive water
will damage it.

Maintenance

Cleaning

Do not immerse the MR-10 Magnetic Locator
in water. Wipe off dirt with a damp soft cloth.
Avoid rubbing too hard. Do not use aggressive
cleaning agents or solutions.

Calibration

The RIDGID MR-10 Magnetic Locator is fac-
tory calibrated and only requires recalibration
if repaired.

Storage

The RIDGID MR-10 Magnetic
WARNING
Locator must be kept indoors when not in use.
Store the machine in a locked area that is out
of reach of children and people unfamiliar with
MR-10 Magnetic Locator. Recommended stor-
age temperature is -13ºF to +140ºF (-25ºC to
+60ºC). Remove the batteries before storage or
shipping to avoid battery leakage.

Service and Repair

WARNING
Improper service or repair can make the
RIDGID MR-10 Magnetic Locator unsafe
to operate.
Service and repair of the MR-10 Magnetic
Locator must be performed by a RIDGID
Independent Service Center.
For information on your nearest RIDGID In -
depen dent Service Center or any service or
repair questions:
• Contact your local RIDGID distributor.
• Visit www.RIDGID.com to find your local
RIDGID contact point.
• Contact Ridge Tool Technical Service De -
partment at rtctechservices@emerson.com,
or in the U.S. and Canada call (800) 519-
3456.

Publicité

Table des Matières
loading

Table des Matières