Adjusting the Recording Level

You can adjust the recording level before starting
recording.
MENU/NO
16
17
18
19
20
U
V
W
X
Y
21
22
23
24
25
Z
.
,
REPEAT
A˜B
A.SPACE
M.SCAN
>
/
25
?
!
(
)
WRITE
CLEAR
P.HOLD
NAME
CHAR
NUM
·
P
p
REC-IT
=
+
r
T.REC
MUSIC SYNC
0
)
CD-SYNC
STOP
START
STANDBY
CD PLAYER
FADER
P
=
+
DIGITAL REC LEVEL
/ANALOG OUT LEVEL
Adjusting the digital recording level
You do not normally need to adjust the digital
recording level. The level is adjusted mainly when the
level of the source is low.
1
Do Steps 1 to 6 in "Recording on an MD" on
pages 9 and 10.
2
Play the portion of the program source with the
strongest signal level.
3
While monitoring the sound, turn outer REC
LEVEL (DIGITAL) (or press DIGITAL REC
LEVEL/ANALOG OUT LEVEL +/–) to adjust the
recording level so that the peak level meters reach
their highest point without turning on the OVER
indication. Occasional lighting of "OVER" is
acceptable.
If the digital signal level of the source is too low,
it may not be possible to set the recording level to
maximum.
REC LEVEL
(DIGITAL/ANALOG)
0
)
r
§
·
P
p
≠ AMS ±
P. HOLD
DIGITAL REC LEVEL
/ANALOG OUT LEVEL +/–
OVER indication
Recording on MDs
4
Stop playing the program source.
5
To start recording, do the procedure starting from
Step 8 in "Recording on an MD" on page 10.
z
The Peak Hold Function freezes the level meter
display at the highest level reached by the input
signal
To turn on the Peak Hold Function by Setup Menu 06
setting
1 While the deck is stopped, press MENU/NO twice to
display "Setup Menu".
2 Turn AMS to select "Setup 06", then press AMS.
3 Turn AMS to select "P.Hold On", then press AMS.
4 Press MENU/NO.
To turn on the Peak Hold Function using the remote
Press P.HOLD to display "P.Hold On."
To turn off the Peak Hold Function, select "P.Hold Off"
in Step 3 above. (Or press P.HOLD on the remote to
display "P.Hold Off".)
Adjusting the analog recording level
1
Do Steps 1 to 6 in "Recording on an MD" on
pages 9 and 10.
2
Play the portion of the program source with the
strongest signal level.
3
While monitoring the sound, turn inner REC
LEVEL (ANALOG) to adjust the recording level.
If the output level of the connected component is
too low, it may not be possible to set the
recording level to maximum.
4
Stop playing the program source.
5
To start recording, do the procedure starting from
Step 8 in "Recording on an MD" on page 10.
15