INSTALLATION
WARNING! THE PUMP OIL MUST BE CHANGED PERIODICALLY; THE OIL CHANGE FREQUENCY MUST BE INCREASED
PROPORTIONALLY TO THE WORKLOAD TO WHICH THE MACHINE IS SUBJECTED. THE OIL MUST BE CHANGED EVERY
15,000 OPERATING CYCLES (CORRESPONDING TO APPROX. 100 HOURS OF OPERATION) FOR MACHINES WITH 4, 8 AND 12
M
/H
PUMPS, EVERY 25,000 CYCLES (CORRESPONDING TO APPROX. 200 HOURS OF OPERATION) FOR PUMPS WITH CAPACITY
3
18 A 100 M
3
/H. IT IS ALSO NECESSARY TO REPLACE THE EXHAUST FILTER (EVERY TWO OIL CHANGES) AND THE OIL FILTER
(ONLY MODELS WITH 60 E 100 M
The oil and filter change frequency increases if liquids or wet products are handled; in such cases, the oil must be changed if the
machine has remained unused for a month or a longer period. A whitish, cloudy or dark and transparent oil means suction of
liquids and moisture, or that the oil is old, respectively.
In models with digital control, A - B - C - D - F, an oil change indicator system is provided: after 15,000 operating cycles, when the
machine is started up and at the end of each cycle, the display indicates an "oil alarm". The number of work cycles performed
can be read at any moment by means of the keys on the control panel (See page 59).
ATTENTION! Do not touch the sealing bars after sealing a bag as they may be very hot (Fig. 1).
WARNING! Do not remove the Teflon cover on the sealing bars; do not use knives or other sharp tools to remove residua from
the sealing bar: always wait for the bars to cool down before using blunt tools.
WARNING! Clean the machine thoroughly after use; clean the plexiglas cover using only a cloth dipped in water, avoid cleaning
liquids and solvents. Use the special products available on the market for cleaning the stainless steel parts. Do not use water or
steam jets as this can damage the machine's electrical equipment.
For all problems (defective working or technical assistance) please contact our Customer Service.
GB
Operation and maintenance manual / Ed. 02 - 2006
/H PUMPS- EVERY 1000 HOURS OF OPERATION) ON THE PUMP.
3
NO!
Fig. 1
48
VACUUM CHAMBER
PACKAGING MACHINES
REV. 00 - Cod.: 1500159