DECLARATION OF CONFORMITY
This product is marked
– Low voltage no. 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 +
A15:2011).
– Electromagnetic compatibility no. 2004/108/CE, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
– RoHS2 no.2011/65/EU.
– Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
– Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation
and/or operating instructions.
L
Cooling Maximum conditions
Outdoor temperature :
Room temperature :
L
Cooling Minimum conditions
Outdoor temperature :
Room temperature :
Tools required for installation (not supplied)
1.Standard screwdriver
2.Phillips head screwdriver
3.Knife or wire stripper
4.Tape measure
5.Level
6.Sabre saw or key hole saw
7.Hacksaw
8. Core bits ø 8
INSTALLATION INSTRUCTIONS
as it satisfies Directives:
OPERATING LIMITS
43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
19.Hammer
10.Drill
11. Tube cutter
12.Tube flaring tool
13.Torque wrench
14.Adjustable wrench
15.Reamer (for reburring)
16.Hex. key
37.4255.101.01
- Split system air conditioner -
L
Heating Maximum conditions
Outdoor temperature :
Room temperature :
L
Heating Minimum conditions
Outdoor temperature :
Room temperature :
Model Combinations:
SEE CATALOGUE
Power Supply:
220 - 240 V ~ 50 Hz
F-GAS Regulation (EC) No. 842/2006
Do not vent R410A into atmosphere: R410A is a
fluorinated greenhouse gas, covered by Kyoto Protocol,
with a Global Warming Potential (GWP) = 1975.
02/2014
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
EG
I
F
D
E

Publicité

Table des Matières
loading

Sommaire des Matières pour Technibel I Serie

  • Page 1 INSTALLATION INSTRUCTIONS - Split system air conditioner - DECLARATION OF CONFORMITY This product is marked as it satisfies Directives: – Low voltage no. 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Page 2: Important

    IMPORTANT! • Ground the unit following local electrical codes. • The Yellow/Green wire cannot be used for any connection Please read before installation different from the ground connection. • Connect all wiring tightly. Loose wiring may cause This air conditioning system meets strict safety and operating overheating at connection points and a possible fire standards.
  • Page 3 Installation site selection - Indoor unit • Select a sufficiently strong location to support the weight AVOID of the unit. • Direct sunlight. • Select a location where tubing and drain hose have the • Nearby heat sources that may affect unit performance. shortest run to the outside.
  • Page 5 ISTRUZIONI DI INSTALLAZIONE - Condizionatore d’aria Split System - DICHIARAZIONE DI CONFORMITÀ Questo prodotto è marcato in quanto conforme alle Direttive: – Bassa Tensione n. 2006/95/CE (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Page 6 IMPORTANTE! • Eseguire la messa a terra dell’unità secondo le norme elettriche locali. Leggere prima di iniziare l’installazione • Il conduttore giallo/verde non può essere utilizzato per collegamenti diversi dalla messa a terra. Questo sistema di condizionamento deve seguire rigidi •...
  • Page 7 Scelta del luogo di installazione unità interna resistente da sostenere il peso dell’unità. EVITARE • Scegliere una posizione in modo che la distanza tra le • L’esposizione diretta al sole. due unità sia la minore possibile. • La vicinanza a fonti di calore che possono danneggiare •...
  • Page 9: Climatiseur Split

    NOTICE D’INSTALLATION - Climatiseur split - DECLARATION DE CONFORMITÉ Ce produit est marqué puisque il est conforme aux Directives: – Basse Tension n° 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Page 10: Veuillez Lire Ce Qui Suit Avant De Commencer

    IMPORTANT! • Effectuez la mise à la terre de l'appareil en respectant les réglementations électriques locales. Veuillez lire ce qui suit avant de commencer • Le câble jaune/vert ne peut en aucun cas être utilisé pour Ce système de conditionnement de l'air répond à des toute autre connexion que celle de la mise à...
  • Page 11: Accessoires Pour L'installation (Non Livres)

    Choix de l'emplacement d'installation - Appareil intérieur RECHERCHEZ • Un emplacement approprié à partir duquel l'ensemble de la EVITEZ pièce peut être climatisé de manière uniforme. • L'exposition directe au soleil. • Un emplacement suffisamment solide pour supporter le poids •...
  • Page 13: Konformitätserklärung

    INSTALLATIONSANLEITUNGEN - Zweirohrsystem-Klimaanlage - KONFORMITÄTSERKLÄRUNG Dieses Produkt ist mit -Zeichen gekennzeichnet, weil es den folgenden Richtlinien entspricht: – Niederspannungsrichtilinie 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Page 14 WICHTIG! Tod verursachen. • Erden Sie das Gerät gemäß den örtlich zutreffenden Bitte vor Arbeitsbeginn lesen Vorschriften. Diese Klimaanlage entspricht strengen Sicherheits- und • Das Gelbe/Grüne Kabel ist für die ausschließliche Betriebsnormen. Verwendung als Erdleitung. • Verbinden Sie Kabel fest miteinander. Lockere Für den Installateur oder Bediener dieser Anlage ist es Verbindungen können...
  • Page 15: Vermeiden Sie

    Wahl des Installationsortes - Innenraumgerät • Wählen Sie eine Stelle, an der der Boden das Gewicht des VERMEIDEN SIE Gerätes tragen kann. • Direkte Sonneneinstrahlung. • Wählen Sie eine Stelle, von der aus die Rohre und der • Wärmequellen in der Nähe des Gerätes, die dessen Wasserablaufschlauch den kürzesten Weg nach darußen Leistungsfähigkeit beeinflussen könnten.
  • Page 17: Declaracion De Conformidad

    INSTRUCCIONES DE INSTALACION - Acondicionador de aire Split System - DECLARACION DE CONFORMIDAD Este Producto está marcado porque responde a las Directivas: – Baja Tensión n° 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Page 18: Precauciones Especiales

    ¡IMPORTANTE! • Realizar la puesta a tierra de la unidad siguiendo las normas eléctricas locales. Leer antes de empezar la instalación • El conductor amarillo/verde no se puede utilizar para conexiones que no sean la de tierra. Este sistema de acondicionamiento cumple medidas rígidas •...
  • Page 19 Dónde instalar la unidad interior • Elegir una posición adecuada desde la que se llegue a todos los rincones. EVITAR • Controlar que el lugar de apoyo es lo suficientemente • La exposición directa al sol. resistente como para soportar el peso de la unidad. •...
  • Page 20 INDOOR UNIT • UNITÁ INTERNA • UNITE INTERIEURE • INNENEINHEIT • UNIDAD INTERIOR Minimum operation and maintenance area. Area minima di esercizio e manutenzione. Surface minimum de fonctionnement et d’entretien. Raumbedarf des Gerätes . Area mínima de funcionamiento y manutención. 2000 max 400 Remove the fixing bracket from the rear part of the unit.
  • Page 21 Before installing the unit it is necessary to remove the front panel: - Open the air intake grille and remove it (detach the safety string). - Remove the front panel by loosening the 4 fixing screws. Prima di installare l’unità è necessario rimuovere il pannello frontale: - Aprire la griglia di aspirazione e rimuoverla (staccare la funicella di sicurezza).
  • Page 22 Wall installation. Place the bracket to the wall and fix the central screw, level it and mark the other holes to drill as shown in the figure (2 holes are optional); fix completely the bracket. Hang the unit to the bracket, mark the holes to drill for the fixing of the unit. Installazione a parete.
  • Page 23 Make the holes for the fixing of the unit. Running power electric cable (with a ground wire) between the two units (see the table of wire section). Check if the quantity and the rawl plugs type supplied are the proper ones for fixing the unit on the wall.
  • Page 24 Remove the electrical box cover to operate on the terminal strip. Rimuovere il coperchio scatola componenti elettrici per accedere alla morsettiera. Enlever le capot de la boîte des composants électriques. Die Abdeckplatte des Klammbrettes entfernen. Quitar la tapa de la caja de los componentes eléctricos para acceder a la regleta de bornes.
  • Page 25 Colocar el cable eléctrico y concitarlo al tablero de bornes (véase esquema de conexiones). Bloquear el cable a la abrazadera de la brida. ADVERTÊNCIA Controlar que los bornes de los cables estér bien sujetos en el tablero de bornes. De otro modo, podrían recalentarlo o provocar problemas en el funcionamiento del acondicionador con riesgo le incendio.
  • Page 26 SYSTEM WIRING DIAGRAM • COLLEGAMENTI ELETTRICI DEL SISTEMA • BRANCHEMENTS ELECTRIQUES DU SYSTEME • ELEKTRISCHE ANSCHLÜSSE DES SYSTEMS • CONEXIONES ELECTRICAS DEL SISTEMA LENGTH, SIZE WIRES AND DELAYED FUSE • LUNGHEZZA, SEZIONE CAVI E FUSIBILI RITARDATI • LONGUEUR, SECTION CABLES ET FUSIBLES RETARDES • KABEL-LÄNGE UND QUERSCHNITT UND TRÄGE SICHERUNGEN •...
  • Page 27 Verbindungskabel B (ABGESCHIRMT): Elektrisches zweipoliges Abschirmkabel; Querschnitt und Länge des Kabels sind in der Installationsanleitungen der Ausseneinheit angezeigt. Das Kabel soll nicht leichter als H05VVC4V5-K -Typ sein (gemäß CEI 20-20 CENELEC HD21 ). Verbindungskabel C (mit Erdungsleitung): Elektrisches mehradriges Kabel; Querschnitt und Länge des Kabels sind in der Installationsanleitungen der Ausseneinheit angezeigt.
  • Page 28: Posizione Del Telecomando

    REMOTE CONTROL UNIT INSTALLATION • POSIZIONE DI INSTALLAZIONE TELECOMANDO • EMPLACEMENT DE LA COMMANDE A DISTANCE • POSITION DER FERNBEDIENUNG • POSICION DE INSTALACION DEL MANDO A DISTANCIA REMOTE CONTROL UNIT INSTALLATION To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places: •...
  • Page 29 WALL-MOUNTED POSITION • Momentarily place the remote control unit in the desired mounting position. • Verify that the remote control unit can operate from this position. • Fix the support at the wall with two screws and hang the remote control unit. POSIZIONE A PARETE •...
  • Page 30 DEFAULT SETTING RESET - RESET IMPOSTAZIONI DI DEFAULT - REMISE A ZERO DES REGLAGES DE DEFAUT - ZURÜCKSETZEN AUF STANDARDEINSTELLUNGEN - RESTABLECER LA CONFIGURACIÓN PREDETERMINADA To operate the unit again with the default setting it is necessary to set the remote control as follows: Filter: ON Night Mode / High Power Mode: OFF Operation mode: AUTO...
  • Page 31 Para restablecer las configuraciones predeterminadas de la unidad interior, ustedes tienen que regular el mando a distancia de la manera siguiente: Filter: ON Night Mode / High Power Mode: OFF Modo de funcionamiento: AUTO Flap: AUTO Temperatura seleccionada: 10°C Ahora, presionar simultáneamente los pulsadores del mando a distancia “FAN” y “I FEEL” durante mas de 5 segundos y soltarlos dirigiendo el mando a distancia hacia la unidad interior.
  • Page 32 PUMP DOWN (See Installation Instruction of Outdoor Unit) Pump down means collecting all refrigerant gas in the Das bedeutet: das Kühlmittel in die Außeneinheit ohne system back into the outdoor unit without losing gas. Gas-Verlust zurückzugewinnen. Man benutzt es, wenn Pump down is used when the unit is to be moved of das Klimagerät in eine neue Position gestellt werden before servicing the refrigerant circuit.
  • Page 33 NOTE: for electrical connections, refrigerant circuit connection and check, consult the Installation Instruction of outdoor unit. NOTA: per collegamenti elettrici, collegamenti del curcuito frigorifero e controlli, guardare il Manuale di Installazione dell’unità esterna. REMARQUE: pour les liaisons éléctriques, les connectiones du circuit de refrigeration et les controles, voir la Notice d’Installation de l’unité...
  • Page 34 REMOTE CONTROL UNIT/INDOOR UNIT ADDRESS • INDIRIZZO TELECOMANDO/UNITA’ INTERNA • ADRESSE TELECOMMANDE/UNITE INTERIEURE • FERNBEDIENUNG/ INNENEINHEIT ADRESSE • DIRECCION MANDO A DISTANCIA/UNIDAD INTERIOR Disconnect the power of indoor unit. Remove the batteries from the remote control unit. Set the microswitches (see table). Insert the batteries in the remote control unit.
  • Page 35 Set SW1 as shown in the table. Impostare SW1 come indicato in tabella. Régler SW1 comme indiqué dans le tableau. Stellen Sie SW1 ein, wie in der Tabelle gezeigt ist. Regular SW1 como indicado en la tabla. REMOTE CONTROL UNIT INDOOR UNIT TELECOMANDO UNITA’...
  • Page 36 REMOTE CONTROL UNIT: HOW TO CHANGE FROM INFRARED TO WIRED • TELECOMANDO: TRASFORMAZIONE DA INFRAROSSI A FILO • TELECOMMANDE: TRANSFORMATION DE INFRAROUGE A FIL • FERNBEDIENUNG: WANDEL VOM INFRAROT ZU KABEL • MANDO A DISTANCIA: CAMBIO DE INFRARROJOS A CABLE GRN/YEL PREPARE THE REMOTE CONTROLLER Detach the plastic cover of the remote controller terminal block.
  • Page 37 PREPARATION DE LA TELECOMMANDE Retirez le couvercle en plastique de la borne de la télécommande. Ouvrez le compartiment des piles, retirer les piles et régler les interrupteurs 5 et 6 en la position OFF. Fermez le compartiment des piles sans mettre les piles (la télécommande sera alimentée par le câble). LIAISON Utilisez un câble électrique tripolaire blindé...
  • Page 40 In order to carry on a constant improvement, our products can be modified without prior notice. Per garantire un costante miglioramento dei nostri prodotti, ci riserviamo di modificarli senza preavviso. Par souci d’amélioration constante, nos produits peuvent être modifiés sans préavis. Unsere Produkte werden laufend verbessert und können Vorankündigung abgeändert Werden.

Ce manuel est également adapté pour:

K2fafib0r5i

Table des Matières