Specifications

• Model: 1000 (A & M) Elite Flow Through Humidifiers (GFI #5730 & #5735)
• Type: Fan Powered Flow Through
• GPD: 18 Based on 120° F / 49° C Plenum Temperature
• Warranty (Years): 10
• Replacement Vapor Pad
• Dimensions (Inches): 16 W x 16-1/2 H x 10-1/2 D
• Weight (Pounds): 15
• Home Size (Sq. Ft.): To 3,000
• Installation: Warm Air / Return Air Plenum
• Plenum Opening (Inches): 14-1/8 W X 12 H
• Pallet Qty: 24
• Cabinet Construction: UV-Stable Automotive Grade Plastic
• Humidistat (Included): "M" Models: MHX3C / "A" Models: GFX3
• Voltage: 120VAC
• In The Box: "M" Models: MHX3C / "A" Models: GFX3 (Incuded) Humidifier,
Humidistat, Control Bypass Damper, 24V Transformer, Solenoid Valve, Vapor Pad
A Models), Installation Instructions, Template, Parts.
Expected Humidity Performance Coverage in Square Feet Based on Construction Type
Model No.
Elite 570
Elite 900
Elite 1000
Outside Design Temperature
Outside Design R.H.
Inside Design Temperature
Inside Design R.H.
Air Changes/hour (AC/H)
Ceiling Height (Feet)
Furnace Plenum Temperature
Furnace Run Time For Calculating Sq. Ft.

Unit Location

• For installation on a vertical surface of the warm air plenum of any forced air furnace.
• WARNING: Disconnect electrical power before beginning installation.
!
• Do not install where temperatures fall below 32°F / 0° C or where plenum temperatures exceed 200° F / 93° C.
For maximum evaporative capacity, install this humidifier on the warm air supply plenum.

Additional Materials That May Be Necessary:

1. 1/4" Diameter plastic supply tubing for cold water applications, or 1/4" copper supply tubing for hot water applications
2. Current sensing relay (Model #GA50 - GFI #7026) / or single pole single throw isolation relay
3. Junction box, 115V grounding outlet, cover and wire
4. 1/2" I.D. Drain hose / 3/4" PVC drain
5. #8 Self-piercing sheet metal screws
6. Misc. wire and connectors
: GA19 (GFI#7919) (Replace 1-2 times per season)
®
Loose
GPD
(0.75 AC/H)
12
800 Sq. Ft.
17
1115 Sq. Ft.
18
1175 Sq. Ft.
Humidifier Performance Baseline Criteria
Model 1000 Humidifier Installation Manual
, Saddle Valve, (GCV3412 Code Valve -
®
Average
(0.50 AC/H)
1200 Sq. Ft.
1650 Sq. Ft.
1770 Sq. Ft.
0° F / -18° C
70% R.H.
70° F / 21° C
30% R.H.
0.30
8
120° F / 49° C
8 Hour /1 Day
Tight
(0.30 AC/H)
2000 Sq. Ft.
2800 Sq. Ft.
3000 Sq. Ft.