Never use the safety valve to vent air pressure in the air tank. It could damage the
safety valve. The valve is set to the maximum permitted pressure by the
manufacturer. Adjustments are not permitted!
WARNING! COMPRESSED AIR CAN BE DANGEROUS. WEAR EYE PROTECTION
WHEN VENTING ANY AIR. COMPRESSED AIR MAY DAMAGE THE EYES OR
CAUSE VISION PROBLEMS.
Replacing the inlet filter and pre-filter
(Fig. 18)
The inlet filter is located inside the compressor crankcase cover.
Inlet filter replacement:
 Pull out the rubber plug by hand (2).
 Remove the used filter (1).
 Insert a new filter and replace the
rubber plug.
Pre-filter replacement:
 Pull out the pre-filter by hand (3).
Replace the element and re-insert.
DK50 PLUS
Fig. 18
Filter element replacement
(Fig. 19)
 Remove the hose (1) from the quick connector.
 Use a wrench (2) to release the filter vessel (3) and remove.
 Pull down on the filter element (4) to remove.
 Insert a new filter element.
 Re-install the filter vessel.
 Gently tighten the filter vessel with the wrench.
 Re-install the hose on the quick connector.
1
Fig. 19
05/2018