Coding within the Sub−D plug
Via the 9−pin Sub−D socket of the CAN addressing module you can connect a coding plug
which defines baud rate and controller address of the basic controller.
In order to permanently set baud rate and controller address in the Sub−D plug, connect the
pins 1 to 8 to pin 9 in a certain way!
Coding plug (view of the soldering side)
Setting the baud rate
Baud rate
[kbaud]
500
250
125
1000
"X"
= connect to pin 9
Example:
Setting the baud rate to 50 kbaud
ð Connect pin 1 to pin 9 and pin 2 to pin 9 by soldering.
Setting the controller address
You can calculate the connections between the pins 4 to 8 and pin 9 required for setting the
controller address by using the values of the following table:
Value
Example:
Setting controller address 13
The sum of the values has to equal 13: 1 + 4 + 8 = 13
ð Connect pins 4, 6 and 7 to pin 9 by soldering.
EDK2174DB DE/EN/FR 4.0
Preliminary works
Coding within the Sub−D plug
Pin 1
−
X
−
50
X
−
Pin 4
Pin 5
1
2
Pin 2
−
−
X
X
−
"−"
= do not connect
Pin 6
4
9
2174CAN004
Pin 3
−
−
−
−
X
Pin 7
Pin 8
8
16
l