Télécharger Imprimer la page

Technical Specifications - BFT CLONIX Instructions D'utilisation Et D'installation

Système radiocommande rolling-code avec clonage

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Thank you for buying this product, our company is sure that you will be
more than satisfied with the product's performance. The product is
supplied with a "Warnings" leaflet and an "Instruction booklet".
These should both be read carefully as they provide important
information about safety, installation, operation and maintenance.
This product complies with the recognised technical standards and
safety regulations. We declare that this product is in conformity with
the following European Directives: 89/336/EEC and 73/23/EEC (and
subsequent amendments).
GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with
this product should be read carefully as they provide important
information about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc)
according to the provisions set out by current standards. Keep
nylon or polystyrene bags out of children's reach.
Keep the instructions together with the technical brochure for
future reference.
This product was exclusively designed and manufactured for the
use specified in the present documentation. Any other use not
specified in this documentation could damage the product and be
dangerous.
The Company declines all responsibility for any consequences
resulting from improper use of the product, or use which is
different from that expected and specified in the present
documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives:It complies with the 89/336/EEC,
1999/5/CEE, European Directive and subsequent amendments.
As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in
order to achieve a good safety level.
The Company declines all responsibility for any consequences
resulting from failure to observe Good Technical Practice when
constructing closing structures (door, gates etc.), as well as from
any deformation which might occur during use.
The installation must comply with the provisions set out by the
following European Directives:It complies with the 89/336/EEC,
1999/5/CEE, European Directive and subsequent amendments.
Disconnect the electrical power supply before carrying out any
work on the installation. Also disconnect any buffer batteries, if
fitted.
Fit an omnipolar or magnetothermal switch on the mains power
supply, having a contact opening distance equal to or greater than
3mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts
for closure (doors, gates etc.) and all system components provided
with an earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing.
Position at least one luminous signal indication device (blinker)
where it can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the
automation safety and correct operation when other manufacturers'
components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly
authorised by the company.
Instruct the product user about the control systems provided and
the manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation
operation area.
Keep radio control or other control devices out of children's reach,
in order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
INSTALLATION MANUAL
personnel.
Anything which is not expressly provided for in the present
instructions, is not allowed.
1) GENERAL OUTLINE
The Clonix receiver combines the characteristics of utmost safety in
copying variable code (rolling code) coding with the convenience of
carrying out transmitter "cloning" operations thanks to an exclusive
system.
Cloning a transmitter means creating a transmitter which can be
included automatically within the list of the transmitters memorised in
the receiver, either as an addition or as a replacement of a particular
transmitter.
Therefore it will be possible to remotely program a large number of
additional transmitters, or for example, replacement transmitters for
those which have been lost, without making changes directly to the
receiver. Cloning by replacement is used to create a new transmitter
which takes the place of the one previously memorised in the receiver;
in this way the lost transmitter is removed from the memory and will no
longer be usable
When coding safety is not a decisive factor, the Clonix receiver allows
you to carry out fixed code additional cloning, which although
abandoning the variable code, provides a high number of coding
combinations.
Using clones when there is more than one receiver (as in the case of
communal buildings),
and especially when a distinction is to be made between clones to be
added to or replaced in individual or collective receivers, could turn out
to be rather difficult. The Clonix receiver cloning system for communal
buildings makes it particularly easy to solve the problem of clone
storage for up to 250 individual receivers.

2) TECHNICAL SPECIFICATIONS

Frequency
Working temperature
Coded by means of
No. combinations
Dimensions
2.1) Receiver
Power supply
Antenna impedance
Relay contact
Max no. radio transmitters to be memorised:
Receiver version
CLONIX 128
CLONIX 512
CLONIX 2048
2.2) MITTO Transmitter
Keys
Power supply
Range
Transmitter versions:
MITTO2 – double-channel, MITTO4 – four-channel.
2.3) TRC Transmitter
Keys:
Power supply:
Range:
Transmitter versions:
TRC1-single-channel, TRC2- double-channel, TRC4- four-channel.
3) ANTENNA INSTALLATION
Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere
with radio reception. In case of insufficient transmitter range,
move the antenna to a more suitable position.
4) PROGRAMMING
Transmitter storage can be carried out in manual mode, or by means
of the UNIRADIO programmer which allows you to create installations
ENGLISH
: 433.92MHz
: -20 / +55°C
: Rolling-code algorithm
: 4 milliard
: see fig.1
: from 12 to 28Vdc - from 16 to 28Vac
: 50Ohm (RG58)
: 1A - 33Vac, 1A - 24Vdc
No. radio transmitters
128
512
2048
: Yellow
: 2 3V Lithium batteries (CR2016 type)
: 50 / 100 metres
: Red
: 12V Alkaline battery
: 50 / 100 metres
CLONIX/TRC/MITTO - Ver. 02 - 9