DRESSER FLUXI 2000/TZ Mode D'emploi page 56

Masquer les pouces Voir aussi pour FLUXI 2000/TZ:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
ANNEX 2: Recommended installation / Installation recommandée / Installations Empfehlung /
Raccomandazioni di installazione / Instalación recomendada / Installatie voorschrift / Önerilen Kurulum
/ Recomendações de instalação / Telepítési ajánlások
Low level perturbation installation
-
≥ 2 DN straight inlet upstream the meter
-
No restriction downstream the meter
Bends in different planes
High level perturbation installation
Example: After a regulator without built-in silencer
DN50-DN150
-
≥ 2 DN straight inlet upstream of the meter
-
No restriction downstream of the meter
DN200-DN500
-
≥ 2 DN straight inlet upstream of the meter + an integrated flow conditioner
-
or ≥ 2 DN straight inlet upstream of the meter + a external flow conditioner
-
or ≥ 9 DN straight inlet upstream of the meter (PTB G13)
-
No restriction downstream of the meter
56
Divergent or convergent
Regulator equipped with built-
in silencer