Regular Safety Checks - Assa Abloy SL500 Manuel D'utilisation

Opérateur de porte coulissante
Masquer les pouces Voir aussi pour SL500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 112

Regular safety checks

To help you fulfill the national/international requirements and to avoid malfunction and risk for in-
juries, we have provided the following checklist.
Do not use the operator if repair or adjustment is necessary.
Disconnect mains power supply
be carried out.
Activate your operator and visually check, fastening and any damage of
operator and cover
1
cables
2
operator mode selector(s)
door and glass (stability)
Also inspect your operator and check visually for
condition of door seals and weather stripping
condition of glazing rubbers
finger protection
7
proper operation; closes slowly and smoothly
any ventilation being obstructed
Set the mode selector to OFF and check that the operator and electromechanical lock (if fitted)
work together. Also check that the lock
Activate the manual activation units
opened appropriately while you pass the entrance/exit.
Then proceed with the automatic activation units
11
Check the safety sensors
See
page
18.
If you are unsure of which type of sensor you have, please contact your ASSA ABLOY Entrance Systems
representative.
If the operator is equipped with break-out system, set the mode selector to
AUTO mode. Push the door(s) manually in the escape direction to ensure
that nothing prevents the door(s) from being open. The door(s) shall stop
Doors in
its operation and it shall be possible to move the door(s) manually. After
escape
the test, restore the door(s) to their normal mode of operation.
doors
If the operator is equipped with automatic opening system, shut off the
power and the door should open and remain open. Restore power and the
door should resume its normal operation.
Let the door close after an impulse ensuring nothing prevents the door from
closing and locking (if regulations require it).
Fire
doors
=
Take appropriate measures.
=
Contact your ASSA ABLOY Entrance Systems representative. For contact information, see last page.
1009875-multi-1-13.0
Daily Action
3
4
5
6
8
really secures the door.
9
, if any, and walk towards the door. Check that the door has
10
in the same way.
if any.
Issue 2022-03-04
12
when cleaning or other maintenance is to
EI
If problem
occurs
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sl510Sl520Sl521

Table des Matières