5. PREPARATIONS BEFORE USE
CAUTION! Set the controller output mode to "OFF" (see section 6.9) to ensure ballasts will not be
accidentally activated during the controller setup. After this, it is safe to either connect the ballasts to the
main power supply or insert the signal cable from the ballasts into the controller.
Note: After 60 seconds of inactivity the controller interface will return to the main menu.
Note: To leave any screen without saving changes, press the BACK key.
Note: More functions can be accessed by clicking the UP key.
1. Ensure you have carried out all applicable steps from section 4.
2. Set the controller output mode to "OFF. "
3. Plug the ballast into the main power supply. The status LED on the ballast should indicate that they are
connected to the controller.
4. Examine whether all LEDs show the correct code according to the EYE HORTILUX DE 1000-VS system
instruction manual. Check the connections when you see an error code. If an overload is indicated on
the controller display, check to make sure you did not make a cabling error connecting a RJ connector.
(see section 4.5/4.6)
5. Verify your controller is ready for use by performing the actions described in this section.
5.1 Localizing the Controller
1. Selecting your default language.
The controller can be set to five languages: Dutch, English, German, French and Spanish.
a. Press ENTER, the controller menu will open.
b. Press the UP/DOWN keys to locate "language" and press ENTER. The Language Screen
will open.
c. Press the UP/DOWN keys to locate your language. Press ENTER to confirm your choice
and return to the controller menu.
2. Switching between 24 hour and AM/PM clock mode and setting the time.
a. Press ENTER, the controller menu will open.
b. Press the UP/DOWN keys to locate "system time" and
press ENTER. The System Time Screen (Figure 8) will
open. In this screen the "clock mode" indication blinks
(Figure 8A)
c. Press the UP/DOWN keys to switch between the
24-hour and the AM/PM-hour clock mode. Press ENTER to
confirm your choice. The "hour" indication (Figure 8B) will
start blinking.
d. Press the UP/DOWN keys to select the correct hour. In
AM/PM-hour Clock Mode, continue pressing to select
AM/PM. Press ENTER to confirm.
e. Use the same procedure to set the minutes (Figure 8C). Press ENTER to confirm your choice and
return to the controller menu.
3. Switch temperature units between °C and °F.
a. Press ENTER, the controller menu will open
b. Press the UP/DOWN keys to locate "temp units" and press ENTER. The Temperature Units Screen
will open.
c. Press the UP/DOWN keys to switch between °C and °F. Press ENTER to confirm your choice and
return to the controller menu.