Note: The displayed temperature may take some time to level out.
Note: If the length of the sensor cable is insufficient to reach the controller, try to relocate the controller. If this is
not possible, the sensor cable may be lengthened an extra 5 meters by using a standard 3.5 mm jack extension
cable. If the message "sensor removed" appears, the plug of the sensor is not (fully) plugged in. Plug the sensor
in completely.
Note: If the message "sensor failure" appears, the sensor is defective. Replace the sensor.
4.3 Connecting Equipment Which Must Be Used During Lights-off Periods
Example: a heater may be activated during lights-off periods.
1. Connect the EEM cable to the cage clamps marked "EEM2" (Figure 7)
2. Connect the auxiliary equipment which must be activated during lights-off periods to the EEM cable
connected to clamps marked "EEM2. "
Main
Room
Auxiliary
equipment
(lights on)
EEM1
1
Auxiliary
equipment
(lights o )
www.eyehortilux.com
EEM2
2
Auxiliary
equipment
(lights on)
Aux
Room
Auxiliary
equipment
(lights o )
7