FIELD BUS NODE PROFIBUS DP

The bus terminal couples an AirLINE station to the Profibus and provides the supply voltages for the
connected participants.
Features:
- Profibus connection in copper wiring
- Data rate: all defined transmission rates up to 12 MBd
- Possibility of supplying all necessary 24 V voltages of an AirLINE station of the small signal level
- Error diagnosis by LEDs at the bus terminal
- Electrical isolation of the field bus segment
9-pole SUB-D Profibus connector
DIP switch for
addressing
NOTE
The Profibus plug is not included in the delivery. Please order the plug according to the
ordering data in the data sheet.
The cover plate is included with the bus terminal. Use this plate to terminate the AirLINE station. The
cover plate has no electrical function. It protects the station from ESD pulses and the user from touching
dangerous voltages.
Type 8644
All manuals and user guides at all-guides.com
D
ESCRIPTION OF
O
S
B
VERALL
YSTEM
Display / LEDs
Supply terminal
- P
ÜRKERT
HOENIX
PH 3