Hot And Cold Water Supply; Water Drain; Electrical Connection; Potential Difference Equaliser - RIHO Olivia Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.5.4

Hot and cold water supply.

The supply pipelines may be installed on the rim of the bath or on the wall for connection to the bath tap. A drainage
overflow installation with water supply can also be supplied. Ask your dealer for Riho overflow-drain combinations with
water supply in the bath.
In case of installation of a drainage overflow installation with water supply in the bath, an aerator water supply should be
installed in the supply line. This is to prevent dirty water from flowing back into the supply pipeline.
In case of doubt, consult a plumbing specialist.
1.5.5

Water drain

Connect the drain pipeline with siphon to the bathroom drain pipeline (min 40 mm). The bathroom drain pipeline must be
positioned at around 25-35 cm from the centre line of the bath's drain, and should have sufficient drainage so that adequate
drainage is ensured (see fig. 6).
service centers.
max. 60°C
1.5.6

Electrical connection

The electrical supply for the installation must be provided with suitable cable
in a waterproof box. The whirlpool is delivered with a 3x1.5mm² or 5x2.5mm² cable (5x2.5mm² in case of whirlpool with
heater or Thermae line).
The whirlpool bath must be connected with cable 3x1.5mm² 230V / 50Hz (RIHO line without heating).
In the case of whirlpool with heater or Thermae line, the connection must be made with a cable 5x2.5mm² 400V / 50Hz or
two cables 3x2.5mm² 230V / 50Hz.
Each cable has to be protected by the appropriate circuit breaker with characteristic C. Cable 3x1.5mm² circuit breaker
10A. Cable 5x2.5mm² (or 2x 3x2.5mm² cable) with 16A circuit breaker and
It is necessary to ensure disconnection in the fixed supply line (eg switch with status indication).
Please
oIn case of doubt, consult a plumbing specialist or contact one of the RIHO assembly or service centers.
1.5.7

Potential difference equaliser

The installation must be supplemented by a separate additional connection wire, which must be led out of the main
potential interconnection of the building or from the switchboard from which the connection for the whirlpool is taken. This
wire must have a solid core with a minimum cross-section of 4-6mm2 and its insulation must be in green-yellow
combination.
IW00290.1
system Hydro/Aero
Figure 5 Inspection hatch(es)
Maximum allowable water temperature is 60°C
In case of doubt, consult a plumbing specialist or contact one of the RIHO assembly or
Fig. 6: Waste instalation
and the connection has to be made
earth leakage circuit breaker
-8-
system Hydro
or Aero
up to 30mA.