Mounting
The CombiTemp™ TCR6 can be mounted in more different ways.
1.
Sensor tube without connection
Baumer offers compression glands fitting Ø6 and Ø8 mm sensor diameter.
This type of mounting is normally used for mounting a sensor direct into a non-pressurized application. If pressurized, ensure that the
connection is tightened correct, so no leakage occur.
A duct channel mounting flange for 8 mm sensor is also available
All threaded connection can be mounted direct into the application without thermowell, however often a thermowell is required to enable the user
to take out the sensor for e.g. calibration without opening the system.
2.
Sensor with male threaded process connection G½A
This G½A connection can be mounted in a Baumer thermowell type 8139 or ZPT4.
The process connection available are R½, G½, G¾, M20
or with hygienic ISO 2852 clamp DN 38
3.
Sensor with male threaded process connection G¾A and G1A and sensors with G½ or G¾ female thread
For these connections a special thermowell can be supplied.
Mount the gland/pocket into the application and install the sensor after the gland/pocket is fixed to the application. This will ensure that the cable is
not twisted during mounting.
Baumer recommend to use a thermal compound filled into the thermowell ensure best possible heat transfer between the pocket and the Com-
biTemp TCR6.
Baumer offers a 6 gram bag Thermal compound, type ZPX1-001.

Electrical connection

Ceramic
terminal
block
Ambient temperature RTD output
Cable diameter for M16
Cable diameter for M20
www.baumer.com
Single
Pt100
element
2-w
3-w
4-w
2-w
White White
Red
Red
Double
Pt100
Pt100
element
White
White
Red
Red
-40...160°C
3...9 mm
8...13 mm
Operating instructions: 11119033 02
CombiTemp™ TCR6
Operating instructions
Temperature
transmitter
Ambient temperature with built in transmitter
Warning
Note: Check the maximum temperature for the cable used.
Pt100
2-w
3-w
4-w
2-w
-
+
4...20 mA
-40...85°C