Télécharger Imprimer la page

Kübler CODIX 130 Mode D'emploi page 5

Masquer les pouces Voir aussi pour CODIX 130:

Publicité

Les langues disponibles

Les langues disponibles

Operating instructions
LCD Display counters
C C O O D D I I X X 1 1 3 3 0 0 / / 1 1 3 3 1 1 / / 1 1 3 3 2 2 / / 1 1 3 3 3 3
The Codix 13X display counters are battery-powered.
They are controlled by contact or voltage pulses. They
may be used in various applications, like e. g.
totalising, parts counting, position acquisition,
Overview
Model
Operating mode
6.130.012.8x0
Count
6.130.012.8x2
6.130.012.8x3
6.131.012.8x0
Cnt.Dir/Up.Dn
6.131.012.8x1
6.131.012.8x3
Up.Dn
6.132.012.8x3
Cnt.Dir
6.133.012.8x0
Quad/Quad2
6.133.012.8x1
Table 1
DC input modes:
Count:
Fast and slow counting inputs
INP A:
Fast counting input
INP B:
Slow counting input
Cnt.Dir:
Counting and counting direction input
INP A:
Counting input
INP B:
Counting direction input
Up.Dn:
Differential counting input
INP A:
Adding counting input
INP B:
Subtracting counting input
Quad:
Phase discriminator input
INP A:
0° counting input
INP B:
90° counting input
Quad2:
Phase discriminator input with
pulse doubling
INP A:
0° counting input
INP B:
90° counting input
Each edge of INP A is counted.
differential counting, etc. In addition, the various
models with specific input types may be extended
using control inputs to select operatin modes and set
for almost any application thanks to adjustable opera-
ting modes.
Counting inputs
INP A
00 ... 0,7 V DC
NPN
07 kHz 00 ... 0,7 V DC
04 ... 30 V DC
PNP
12 kHz
10 ... 260 V AC/DC AC/DC 30 Hz
00 ... 0,7 V DC
NPN
07 kHz
04 ... 30 V DC
PNP
12 kHz
10 ... 260 V AC/DC
AC/DC
30 Hz
10 ... 260 V AC/DC
AC/DC
30 Hz
00 ... 0,7 V DC
NPN
03 kHz
04 ... 30 V DC
PNP
06 kHz
Options:
AC input modes:
Count:
Cnt.Dir:
Up.Dn:
INP B
NPN
00 ... 0,7 V DC
NPN
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC
AC/DC
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
x = 5: no backlight
x = 6: with backlight
Counting and reset inputs
INP A:
AC/DC counting input
INP B:
AC/DC reset input
Counting and counting direction input
INP A:
AC/DC counting direction input
INP B:
AC/DC counting input
Differential counting input
INP A:
AC/DC subtracting counting input
INP B:
AC/DC adding counting input.
30 Hz
0–
07 kHz
12 kHz
30 Hz
30 Hz
03 kHz
06 kHz

Publicité

loading

Ce manuel est également adapté pour:

Codix 131Codix 132Codix 133