No. Parameter
Function
Name
Explanation
59
Activation Time for Electronic
Thermal Protection Function
60
Over-torque
Over-torque
Detection
detection mode
61
Over-torque
detection level
62
Over-torque
detection time
63
Reserved
64
User Defined
Displays user
Parameter
defined parameter
Displayed
on digital keypad/
display
65
Coefficient K
Coefficient for line
speed
Parameter
Value
d30 - d300 s
d00:Over-torque detection not
enabled
d01:Over-torque detection during
constant speed operation.
Drive operation halted after
over-torque (OL2).
d02:Over-torque detection during
constant speed operation.
Operation continues after
over-torque detection (OL2).
d03:Over-torque detection during
operation.
Drive operation halted after
over-torque (OL2).
d04:Over-torque detection during
operation.
Operation continues after
over-torque detection (OL2).
d30 - d200%
d0.1 - d10.0 s
d00:Display the drive output
frequency (H)
d01:Display user-define setting (V)
d02:Display user-define setting (r)
d03:Display user-define setting (L)
d04:Display user-define setting (%)
d05:Display the counter value (c)
d06:Display the program freq. (F)
d07:Display the par. setting (Pr.00)
d08:Reserved
d09:Displays motor current (A)
d10:Displays Fwd/Rev mode
d0.1 - d160.
13
Factory
Setting
d60
d00
d150
d0.1
d06
d1.0