Vitrifrigo D20A Manuel D'instructions page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Appliance recessing with ventilated condenser
The size of the front opening to be prepared for recessing the appliance must respect the
dimensions of the refrigerator (see annex 1). The recess must respect the minimum distances
between the appliance and the surrounding structure and it must have suitable ventilation
openings communicating directly with the open space in the room, in order to obtain correct
air circulation by means of the chimney effect, as indicated in annex 2.
The recess must ensure that all possible live parts of the appliance are not directly accessible
as well as the ventilation openings, by fitting them with suitable grilles.
The grilles must have openings with max. dimension of 5 mm.
The envisioned ventilation openings are:
-
with dimension no less than 120 mm in height for the dimension of the refrigerator in
width if positioned behind, which must always be associated to another opening of
at least 120x12 mm placed on the side of the condenser (anx.2).
-
with dimensions 120x120 mm if positioned on both sides, as per annex 2.
The minimum distances between the various parts of the appliance and the recess
structure must not be less than 75mm. (anx.2)
For recess situations in spaces where the minimum distance of 75mm is respected only in the
rear part of the appliance, make the ventilation openings on the same side respecting the
indications for the position, number and dimensions shown in anx.2.
In all the situations of the described ventilation openings, only the minimum distance of 75mm
from the sides of the appliance may not be observed.
Appliance recess, with ventilated remote motor.
The size of the front opening to be prepared for recessing the appliance must respect the
dimensions of the refrigerator (see annex 1). The recess must respect the minimum distances
between the remote motor and the surrounding structure and it must have suitable ventilation
openings communicating directly with the open space in the room, in order to obtain correct
air circulation by means of the chimney effect, as indicated in annex 2.
The recess must ensure that all possible live parts of the appliance are not directly accessible
as well as the ventilation openings, by fitting them with suitable grilles. The grilles must have
openings with max. dimension of 5 mm.
The ventilation openings must have dimensions no smaller than 120x120 mm and positioned
on both sides, as per annex 2.
Appliance recess for campers, caravans and motor-homes.
To install the refrigerator or fridge units in a caravan, camper van, motor home etc.
make the recess space in the vehicle with ventilation vents directly on the outside, fitted
20
ENG

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

D30a

Table des Matières