Universal Wall-Sleeve Dimensions - Whirlpool WHAT081-HAW Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DIMENSIONS
PART
1" x 3/4" x 14"
Seal Sponge
1" x 3/8" x 14"
Seal Sponge
1" x 3/8" x 25"
Seal Sponge
1" x 1½"x 25"
Seal Sponge
1" x 1½" x 14"
Seal Sponge
1" x 1½" x 84"
Seal Sponge
3¾" x 1½" x 4"
Seal Cotton
3/4" x 1½" x 17"
Seal Cotton
Universal Wall—Sleeve Dimensions
QUANTITY
1. Identify the wall-sleeve brand installed in the wall, and make
sure that dimensions of wall-sleeve are as per the below table:
2
Standard Dimension
2
NOTE:
3
All wall sleeves, used to mount the new air conditioner must
■ ■
be in sound structural condition and have a rear grille that
securely attached to the sleeve, or rear flange that serves as a
stop for the air conditioner.
3
If non-Whirlpool brand wall-sleeve installed, make sure that
■ ■
the dimension is suitable for the product.
2
The selected wall-sleeve must be installed and fastened to
■ ■
the wall with the screws.
IMPORTANT: When installation is complete, replacement unit
1
must have rearward slope as shown in below figure:
4
2
2. Remove the old air conditioner from wall sleeve and prepare as
follows:
Clean interior (Do not disturb seals).
Check the wall sleeve to make sure that it is securely
attached to the wall before installing.
Repair painted surface if needed.
3. If the ground wire hole does not exist, drill a 3/16" pilot hole for
the ground screw through the left hand side of the sleeve, in
a clear area about 3 inches max. back from the front edge as
shown in below figure:
4. Pull the loose end of the ground wire out of the front of
the sleeve and bend it away from the opening. This will be
attached to the air conditioner once installed.
Wall-sleeve Dimensions
Type
Height
15¾"
Wall Sleeve
Rear
3"
Max
Wall sleeve to unit
Grounding.
1"
Width
Depth
26"
16¾"
1/4" to 5/16"
Front
Level
3/16"Pilot Hole
Sleeve
5