HPD
Battery flat
Tag fault
RFID fault
Suction motor temperature
Brush temperature
O.C. Suction motor
O.C. Drive
Update FW main board
Update FW service board
Flashing light fault
Solenoid valve fault
Pump fault
Brush fuse
Suction motor fuse
Drive lever pressed when starting.
Drive lever potentiometer not adjusted.
Battery voltage less than 21.4 V - GEL /
20.5 V - ACID. Flat or degraded batteries.
Faulty key. Faulty instrument panel
antenna board
Faulty key. Faulty instrument panel
antenna board
Excessive motor effort. Faulty functions
board. Faulty suction motor.
Excessive motor effort. Faulty functions
board. Faulty motor.
Excessive motor effort. Faulty functions
board. Faulty suction motor.
Excessive vehicle effort. Faulty drive
board. Electric brake engaged.
Software update.
Software update.
Faulty wiring. Faulty flashing light. The
flashing light is broken. The flashing light
has been enabled in the Technical menu
but it is not fitted on the machine.
Faulty wiring. Faulty solenoid valve.
Solenoid valve broken.
Faulty wiring. Faulty pump. The pump
is broken. The pump has been enabled
in the Technical menu but it is not fitted
on the machine.
Excessive motor effort. Faulty brush
motor contactor. Motor fuse blown.
Excessive motor effort. Faulty brush
motor relay. Motor fuse blown.
Release the drive lever when starting
the machine. Check potentiometer
adjustment.
Recharge the batteries.
Replace the batteries.
Replace the key. Replace the instrument
panel antenna board-reed.
Check the wiring.
Replace the key. Replace the instrument
panel antenna board-reed.
Check the wiring.
Check the suction motor. Replace
functions board. Replace the suction
motor.
Check the motor. Replace functions
board. Replace the motor.
Check the suction motor. Replace
functions board. Replace the suction
motor.
Check the motor. Replace the drive
board. Check the electric brake.
Do not remove the key during
the update.
Do not remove the key during
the update.
Check the wiring. Check the flashing
light. Replace the flashing light. Correct
the settings in the Technical Menu.
Check the wiring. Check the solenoid
valve. Replace the solenoid valve.
Check the wiring. Check the pump.
Replace the pump. Correct the settings
in the Technical Menu.
Check the motor. Replace the contactor.
Replace the fuse.
Check the motor. Replace the relay.
Replace the fuse.
Parts & Operations Manual