Safety General Regulations; Application; Norms And Regulations - elco R600 Serie Notice D'installation Et D'emploi

Masquer les pouces Voir aussi pour R600 Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Safety
General regulations

Application

Norms and regulations

General regulations
This documentation contains important
information, which is a base for safe
and reliable installation, commissioning
and operation of the R600 boiler. All
activities described in this document
may only be excecuted by authorized
companies.
Changes to this document may be ef-
fected without prior notice. We accept
no obligation to adapt previously deliv-
ered products to incorporate such
changes.
Only original spare parts may be used
when replacing components on the
boiler, otherwise warranty will be void.
Application
The R600 boiler may be used for heat-
ing and hot water production purposes
only. The boiler should be connected to
closed systems with a maximum tem-
perature of 100ºC (high limit tempera-
ture), maximum setpoint temperature is
90ºC.
Norms and regulations
When installing and operating the
boiler, all applicable norms (european
and local) should be fulfilled:
Local building regulations for install-
ing combustion air and flue gas sys-
tems;
Regulation for connecting the boiler to
the electrical appliance;
Regulations for connecting the boiler
to the local gas network;
Norms and regulations according to
safety equipment for heating systems;
Any additional local laws/regulations
with regard to installing and operating
heating systems.
The R600 boiler is CE approved and
applies to the following European
standards:
92 / 42 / EEC
Boiler efficiency directive
90 / 396 / EEC
Gas appliance directive
73 / 23 / EEC
Low voltage directive
89 / 336 / EEC
EMC directive
EN 656
Gas-fired central heating boilers –
Type B boilers of nominal heat input
exceeding 70 kW but not exceeding
300 kW
EN 15420
Gas-fired central heating boilers -
Type C boilers of nominal heat input
exceeding 70 kW, but not exceeding
1000 kW
EN 15417
Gas-fired central heating boilers -
Specific requirements for condensing
boilers with a nominal heat input
greater than 70 kW but not exceeding
1000 kW
EN 13836
Gas fired central heating boilers -
Type B boilers of nominal heat input
exceeding 300 kW, but not exceeding
1000 kW
EN 15502-1
Gas-fired central heating boilers -
Part 1: General requirements and
tests
EN 55014-1
Electromagnetic compatibility - Re-
quirements for household appliances,
electric tools and similar apparatus -
Part 1: Emission
EN 55014-2
Electromagnetic compatibility - Re-
quirements for household appliances,
electric tools and similar apparatus -
Part 2: Immunity - Product family
standard
EN 61000-3-2
Electromagnetic compatibility (EMC) -
Part 3-2: Limits - Limits for harmonic
current emissions (equipment input
current 16 A per phase)
EN 61000-3-3
Electromagnetic compatibility (EMC) -
Part 3-3: Limitation of voltage
changes, voltage fluctuations and
flicker in public low-voltage supply
systems, for equipment with rated
current 16 A per phase and not sub-
ject to conditional connection
EN 60335-1
Household and similar electrical appli-
ances - Safety - Part 1: General re-
quirements
EN 50165
Household and similar electrical appli-
ances - Safety - Part 2-102: Particular
requirements for gas, oil and solid-
fuel burning appliances having
electrical connections
Additional national standards
Germany:
RAL - UZ 61 / DIN 4702-8
Switzerland:
SVGW
Austria:
ÖVGW
Netherlands:
NOx staatsblad 344 (1994)
GASKEUR BASIS
GASKEUR SV
GASKEUR HR107
Belgium:
HR TOP
3

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R601R602R603R604R605R606 ... Afficher tout

Table des Matières