4.2.1 DC Voltage
Range
200mV
2V
20V
200V
1000mV
Input impedance: 10MΩ
Maximum input voltage: 1000Vdc or 750Vac RMS,
250Vdc or ac RMS with the measuring range of 200mV
4.2.2 AC Voltage
Range
2V
20V
200V
750mVV
Input impedance: 10MΩ
Maximum input voltage: 1000Vdc or 750Vac RMS, 250Vdc or ac RMS with the
measuring range of 200mV.
Frequency response: 40Hz-400Hz sine wave RMS (average response)
The frequency response is 200Hz for 750V
4.2.3 Frequency
Range
20kHz
2kHz
Input voltage range: 200mV-10V ac RMS
Resolution
0,1mV
1mV
10mV
100mV
1V
Resolution
0,1mV
1mV
10mV
100mV
Resolution
10Hz
1Hz
34
KPS-MT40 • Digital multimeter
Accuracy
±(0,5% of reading + 2 digits)
±(0,8% of reading + 2 digits)
Accuracy
±(0,8% of reading + 3 digits)
±(1,2% of reading + 3 digits)
Accuracy
±(2,0 of reading + 5 digits)
±(1,5 of reading + 5 digits)