2.2 START-UP

2.2.1 CONNECTION OF THE REMOTE CONTROL AND SELF-CALIBRATION

To connect the remote control to the In-Wash it is necessary to:
1
2
CR 2032 (x2)
CR 2032 (x1)
1- Place the batteries inside the remote control.
2- Open water supply valve
3- Activate the power to supply the In-Wash.
4- After connecting the power, you have 60 seconds to link the remote control, pressing simultaneously the Drying and Stop buttons on the remote
control for 5 seconds.
5- A beep will be heard and all the LEDs on the remote light up, as a signal that it is connected. A self-calibration process starts for 120 seconds during
which water flows from the e-bidet nozzle window.
Do not disconnect the device during this process.
Should the connection be incomplete, repeat the process starting from step 2.

2.2.2 USE OF THE PRODUCT

The In-Wash has a small internal water tank that is cold in stand-by conditions.
When the user detector detects a seated user, the preheating process is activated.
The preheating takes place at 36º. The functions may be activated at any time, but if they are activated too soon, the water will not have time to reach
the established temperature; therefore it is recommended a minimum preheating period of 30 seconds from the moment the In-Wash detects the user
until any water function is activated.
When a function is activated, the In-Wash carries out a cleaning of the nozzle before its use.
When the function is finished, a subsequent cleaning process of the nozzle takes place for 10 seconds.
The functions may only be activated when the cover is open and the device detects a user.
See Fig. 2
It is possible to modify the pre-set standard values, customising them to suit the customer´s needs. See section 3.4.1
When pressing any button of the remote control, the leds are activated, informing us of the active function and the settings that have been selected.
The leds switch off 5 seconds after showing that information.
3
4
ON
Max. 60 s.
5
AUTO-CALIBRACIÓN
5 s.
5 s.
120 s.