Constantly check the filling level in the liq-
uid container when filling large quantities of
liquid.
Emptying the liquid container
See graphics page for illustration
1. Switch the device off and disconnect it
from the power supply.
2. Move the device to the waste water tank.
3. Empty the liquid container:
a Connect the drain hose to the upper
hose coupling.
Illustration F
b Hold the drain hose over a suitable
collecting container and drain the con-
tents.
4. Dispose of or reuse the contents in ac-
cordance with statutory regulations.
Emptying the liquid container by
tilting
See graphics page for illustrations
1. Switch the device off and disconnect it
from the power supply.
2. Move the device to the waste water tank.
3. Remove the suction head (see chapter
Removing the suction head).
4. Remove all accessory parts.
5. Prepare the liquid container for empty-
ing:
 Using the tilting device Tc (Device
with tilting device Tc)
a Open the lock of the liquid container.
Illustration G
 using the crane grommet (Device
without tilting device Tc)
a Lift the device onto the crane grommet
(see chapter Device description) us-
ing suitable lifting gear.
DANGER
Failure to observe the weight
Risk of injury from falling device
Observe the applicable accident prevention
guidelines and safety instructions.
Every time before lifting, check to ensure
correct functioning of the lifting device.
Only lift the device via the provided crane
grommet.
Ensure that there will be no unintentional
unhooking of the lifted load.
The crane may exclusively be operated by
qualified staff.
No people may be located within the haz-
ard zone of the crane.
Do not leave the device hanging unattend-
ed on the crane.
6. Tip the container with the push handle.
Illustration H
7. Dispose of or reuse the contents in ac-
cordance with statutory regulations.
8. Fit and lock the suction head.
Cleaning the liquid container
Note
Bacterial contamination may occur through
the use of water-based cooling lubricants.
Wear suitable protective clothing when re-
moving deposits.
1. Empty the container.
2. Remove deposits in the container.
3. Dispose of the deposits in accordance
with the applicable regulations.
4. Remove chippings and deposits from
the support plates.
Illustration I
Removing the suction head
See graphics page for illustrations
1. Switch off the device and disconnect
from the power supply.
2. Open the lock for the suction head.
Illustration J
3. Remove the suction head and put to one
side.

Finishing operation

1. Switch off the device using the on/off
switch
2. Empty and clean the liquid container.
3. Remove the accessories and clean and
dry them as necessary.
Note
Empty the vacuum cleaner after every use.
Allow the vacuum cleaner to dry with the
container open.