Additional issues to be inspected by the in-
staller upon service replacement:
1. The drain pump must be level.
2. No pinched water lines.
3. No interference with electrical cords or wiring.
4. The drain pump should not set on any obstacles, wir-
ing, etc.
5. Secure all hose clamps leading to and from the drain
pump.
6. Insure that the vent tube height is adequate - 18 inch
minimum.
7. Insure that drain height is adequate - maximum of 8
foot.
8. Insure that drain length is adequate - maximum of 20
foot.
9. Checked for water leaks after installation of the drain
pump.
10. Check for vibrations caused by improper installation.
11. Insure that there is no interference with back access
cover.
12. Insure that the hole grommets are in place at each
location
so that any vent or drain tubes do not rub on any sharp
surfaces.
DRAIN PUMP REMOVAL INSTRUCTIONS
Ice machine
power cord
Figure 29