Drain Pump Removal Instructions - AGA marvel 30iMT Instructions D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Drain Pump Removal Instructions:

1. Unplug ice machine from the electrical supply and re-
move the rear access cover from the ice machine. (See
page 6 for instructions).
2. Unscrew the leveling leg in the back corner until the
end of the threaded portion is flush with the threaded
nut insert in the base. (see Figure 28 ).
3. Unscrew the 4 hose clamps and remove the 3 hoses
from the front of the drain pump. (See Figure 28).
4. Rotate the drain pump and remove from the ice ma-
chine, (See Figure 27). It may be necessary to discon-
nect the ground wire connection in the back flange of
the cabinet. (See Figure 28).
5. Disconnect the ice machine power cord from the drain
pump (See Figure 29).
6. To drain water from the pump follow step 13 through 15
on page 22.
7. Installation of drain pump is reverse of this procedure.
Remove these 4 hose
clamps, then remove the 3
tubes from the drain pump
Unscrew the leveling leg so
the end of the threads is flush
with the top of the nut insert.
DRAIN PUMP REMOVAL INSTRUCTIONS
Rotate drain pump
and remove from
back of ice machine.
Figure 28
24
Drain valve
Figure 27
It may be necessary to disconnect
this electrical connection on factory
installed drain pumps
Drain pump
ground wire
connection

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour AGA marvel 30iMT

Ce manuel est également adapté pour:

30imat3oimtMpro30imt

Table des Matières