Programming The Sun Protection And Twilight Function - Siemens DELTA i-system Komfort 5TC1 Serie Notice De Montage Et De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Sun protection and twilight function
Info: The delays of 2 respectively 15 minutes are necessary to prevent premature
movements of the blind/shutter in the event of short-time variations in brightness.
The sun protection function can be deactivated by depressing the
The twilight function
The twilight function lowers the blind/shutter automatically when it gets dark. As soon as
the brightness falls below the preset value, the moon symbol starts flashing. 4 minutes
later, the blind/shutter is lowered down the limit stop.
The twilight function is activated 2 hours before the Astro sunset time only to prevent the
blind/shutter from being moved down inadvertently during the day when the sensor is
covered up.
If the twilight function is to be executed in conjunction with switching times, these must
be programmed with Astro values.
In this case, the twilight function replaces the Astro sunset time.
Switching times without Astro component are executed at the programmed time inde-
pendent of brightness.

7.1 Programming the sun protection and twilight function

Before programming observe the following instructions:
Attach the sensor to the window pane and connect it to the attachment before
starting to program the sun / twilight function.
Using the sun protection or the twilight functions without a sensor being connected
may lead to inadvertent movements of the blind/shutter.
Time
Setting the current data
Programming memory A
Programming memory B
Programming memory C
Setting the sun / twilight value
Shifting astro times
Learning louver running time
1. Depress the
Set
2. Use the
or
symbols
.
3. Confirm by depressing the
key briefly.
key until prog is displayed.
key to select the
key briefly.
Set