Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PRESSURIZING
1. Make sure the bypass system is in 'bypass' position.
2. Make sure the electronic controller of the water filter is
in service mode.
3. Open the mains water supply.
4. Open a cold treated water faucet nearby the water filter
and let the water run for a few minutes until all air is
purged and all foreign material that may have resulted
from the installation is washed out; close the tap.
5. Gently pressurize the water filter, by putting it into
service:
factory bypass:
1. open the 'outlet' valve;
2. slowly open the 'inlet' valve.
3-valve bypass:
1. close the 'bypass' valve;
2. open the 'outlet' valve;
3. slowly open the 'inlet' valve.
6. After 2-3 minutes, open a cold treated water faucet
nearby the water filter and let the water run until all air is
purged from the installation and the filter medium is
properly rinsed (it is normal for the rinse water to show
some discoloration!); let the water run until the rinse
water is clear; close the tap.
7. Check the water filter and all hydraulic connections for
leaks.
During the passage through the compressed air
chamber, the treated water will get highly oxygenated. As a
consequence it may become slightly non-transparent (milky
appearance) when it flows from the tap into a glass. This is
totally harmless for the quality of the treated water and will
disappear rapidly if the water is left standing for a moment!
ELECTRONIC CONTROL PANEL
8. Program the electronic controller.
PERFORM REGENERATION
We strongly recommend to postpone the execution of
this 'start-up' regeneration by 24 hours. The filter medium
needs sufficient time to absorb water and reach its normal
service weight. If the regeneration is performed too soon,
the filter medium may be pushed against the top distributor
during the backwash cycle, possibly resulting in loss of filter
medium or damage to the top distributor.
9. Manually initiate a regeneration, by pressing the scroll
button repeatedly until the display shows:
Regen in 10 sec
10. Leave the water filter in this position; the countdown
timer will countdown to 0 sec and start a regeneration.

START-UP

Page 7