OPERATING CONDITIONS & REQUIREMENTS
APPLICATION LIMITATIONS:
− pH: for Iron removal: 6,8 - 9,0
for Manganese removal: 8,0 - 9,0
for Iron & Manganese removal: 8,0 - 8,5
− maximum contaminant content:
Iron (Fe
Manganese (Mn
Hydrogen Sulfide (H
− organic matter: max. 4,0 mg/L; higher level may hinder the correct operation of
the system.
− chlorine: max. 1,0 mg/L
− iron bacteria: if iron bacteria are present, frequent service may be necessary,
while the life of the system may be limited; by properly controlling the iron
bacteria with chlorine or another approved method of bacterial reduction, the
system will function properly.
OPERATING PRESSURE: min. 1,4 / max. 8,3 bar
− this system is configured to perform optimally at an operating pressure of 3 bar
(±½ bar); in case of a higher operating pressure the performance may be affected
negatively!
− if installed on a well, verify that the well pump is powerful enough to provide
sufficient flow rate for the regeneration.
− check water pressure regularly.
− install a pressure reducer ahead of the water filter if necessary.
OPERATING TEMPERATURE: min. 4 / max. 38 °C
− do not install the water filter in an environment where high ambient
temperatures (e.g. unvented boiler house) or freezing temperatures can occur.
− the water filter cannot be exposed to outdoor elements, such as direct sunlight
or atmospheric precipitation.
− do not install the water filter too close to a water heater; keep at least 3 m of
piping between the outlet of the water filter and the inlet of the water heater;
water heaters can sometimes transmit heat back down the cold pipe into the
control valve; always install a check valve at the outlet of the water filter.
ELECTRICAL CONNECTION: 230V-50Hz
− this water filter only works on 24VAC; it is equipped with a 230/24V-50Hz
transformer; always use it in combination with the supplied transformer.
− make sure to plug the transformer into a power outlet, which is installed in a dry
location, with the proper rating and over-current protection.
2+
)
2+
)
S)
2
Page 5
15 mg/L
2 mg/L