Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INLET & OUTLET
Check the water pressure at the place of installation of
the water filter; it should never exceed 8,3 bar.
We strongly recommend the use of flexible hoses to
connect the water filter to the water distribution system; use
hoses with a large diameter in order to limit the pressure
loss.
If the water filter is not equipped with the factory bypass
(optional), we strongly recommend to install a 3-valve
bypass system (not included with this product!) to isolate the
water filter from the water distribution system in case of
repairs. It allows to turn off the water to the water filter,
while maintaining (untreated) water supply to the user.
To prevent air from escaping from the compressed air
chamber, make sure the inlet line runs vertically upwards
into the water filter. If this is not possible, install a check
valve in the inlet line.
WITH FACTORY BYPASS (optional)
Picture 1
= mains water supply (untreated water)
= inlet of water filter (untreated water)
= outlet of water filter (treated water)
= house/application (treated water)
1. Screw the factory bypass onto the in/out ports on the
control valve ( & ); make sure to install the gasket
seals. Tighten the nuts firmly by hand.
2. Screw the connection kit with nuts onto the factory
bypass ( & ); make sure to install the gasket seals.
Tighten the nuts firmly by hand.
3. Connect the mains water supply to the adaptor on the
inlet port of the factory bypass ( ).
4. Connect the house/application to the adaptor on the
outlet port of the factory bypass ( ).
WITH 3-VALVE BYPASS SYSTEM (not included)
Picture 2
= inlet of water filter (untreated water)
= outlet of water filter (treated water)
1. Install the 3-valve bypass system.
2. Screw the connection kit with nuts onto the in/out ports
on the control valve ( & ); make sure to install the
gasket seals. Tighten the nuts firmly by hand.
3. Connect the 3-valve bypass system to the adaptors on the
in ( ) and out ( ) port of the control valve.
4. Connect the mains water supply to the inlet of the 3-valve
bypass system.
5. Connect the house/application to the outlet of the 3-valve
bypass system.
EN - English

INSTALLATION

We recommend the use of a stand pipe with air trap.
To prevent backflow from the sewerage system into the
water filter, always install and use the included air gap with
double hose barb, to connect the drain hose to the sewerage
system.
Lay-out the drain hose in such a way that pressure loss
is minimized; avoid kinks and unnecessary elevations.
Make sure that the sewerage system is suitable for the
rinse water flow rate of the water filter.
Picture 3
1. Install the air gap to the sewerage system; it fits over a
32 mm pipe or inside a 40 mm pipe adaptor. Ensure a
permanent and watertight connection.
2. Connect a 13 mm hose to the drain connection of the
control valve ( ); secure it by means of a clamp.
3. Run the drain hose to the air gap and connect it to one of
the hose barbs; secure it by means of a clamp. This drain
line operates under pressure, so it may be installed higher
than the water filter.
Picture 4
1. Plug the transformers output lead into the socket on the
control valves power cord; secure it by means of the
TwistLock clamp.
2. Plug the transformer into an electrical outlet.
Picture 5
Make sure the air injection system is installed in vertical
position, with the check valve and air intake filter screen
pointing upwards. Rotate it to this position if necessary.
Page 6
DRAIN
ELECTRICAL
AIR INJECTION SYSTEM

Publicité

Table des Matières
loading

Table des Matières